ACC SNAPlus2 Link Software User’s Guide Edition 4 HP 9000 Networking Manufacturing Part Number: Z7485-90001 E0400 © Copyright 2000 Hewlett-Packard Company
Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Warranty.
This software is based in part on the Fourth Berkeley Software Distribution under license from the Regents of the University of California. © copyright 1980, 1984, 1986 Novell, Inc. © opyright 1986-1992 Sun Microsystems, Inc. © copyright 1985-86, 1988 Massachusetts Institute of Technology. © copyright 1989-93 The Open Software Foundation, Inc. © copyright 1986 Digital Equipment Corporation. © copyright 1990 Motorola, Inc.
Publishing History The manual publishing date and part number indicate its current edition. The publishing date will change when a new edition is published. Minor changes may be made without changing the publishing date. The manual part number will change when extensive changes are made. Manual updates may be issued between editions to correct errors or document product changes. To ensure that you receive the updated or new editions, you should subscribe to the appropriate product support service.
Contents 1. About ACC SNAPlus2 Link Software Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Product Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Requirements and Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 OS Versions Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 ACC Hardware Supported . . . . . . . . . . . . . . . . .
Contents SNA/ACC Software Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SNAplus2 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SNAplus2 Over SNA/ACC Verification . . . . . . . . . . . . . . . . . . . . . . 30 3. Using SNAplus2 via SNA/ACC Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Checking SNAplus2 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 About ACC SNAPlus2 Link Software 9
About ACC SNAPlus2 Link Software Introduction Introduction The ACC SNAPlus2 Link Software product allows Hewlett-Packard’s HP-UX SNAplus products to be used with SDLC over Multi-channel ACC Multiplexer products. This manual provides installation and configuration information that is specific to the SNA/ACC Software. Refer to the ACC Error Guide for information about SNA/ACC error codes.
About ACC SNAPlus2 Link Software Product Features Product Features SNA/ACC software enables the use of HP-UX SNAplus2 products over SDLC via the multi-channel, multi-protocol ACC Interface. The SNA/ACC product includes the following features: • Installs with SD-UX utility swinstall • Auto-Dial feature fully supported • SNAplus2 communicates with ACC via either SDLC or X.
About ACC SNAPlus2 Link Software Requirements and Considerations Requirements and Considerations OS Versions Supported The ACC SNAPlus2 Link Software product supports HP-UX 11.0. ACC Hardware Supported The ACC Base Software product and the ACC and X.
About ACC SNAPlus2 Link Software Requirements and Considerations Using SNA Over X.25 To use SNAplus2 over X.25 with the ACC cards, both the SNAplus2 and the X.25/ACC products must be installed on your system. The SNA/ACC product is not required. ACC Hardware Not a Pre-requisite It is not a requirement that you install your ACC cards first before installing the pre-requisite ACC software mentioned above or the ACC SNAPlus2 Link Software.
About ACC SNAPlus2 Link Software The SNAPlus2 Link with SNA/ACC The SNAPlus2 Link with SNA/ACC The diagram shown below illustrates the relationship between the SNAplus2 product and the SNA/ACC software described in this document. SNAplus2 X.
About ACC SNAPlus2 Link Software Supported Devices Supported Devices HP-UX SNAPlus2 Link software provides services with any compatible device conforming to IBM’s Logical Unit types 0-3 and LU 6.2 architectures, which allows for APPC, LUA and CPI-C data exchanges in a Systems Network Architecture (SNA). SNA/ACC provides HP-9000/SNAplus2 servers with expanded (multi-channel and multi-protocol) WAN access at conventional data rates via the HP-PB (NIO) 8-Channel and EISA 8-Channel ACC Multiplexer interfaces.
About ACC SNAPlus2 Link Software Mode of Operation Mode of Operation SNA/ACC supports the running of SNAPlus2 Link in a client/server environment, provided the required LAN/9000 Series 700 or Series 800 software components, such as, the ARPA/Berkeley Sockets are configured. Support for running SNAPlus2 Link using QLLC via SNA/ACC requires installation of ACC and X.25/9000 software.
About ACC SNAPlus2 Link Software References References For information on installing the ACC Base Software product and how to start up the ACC Subsystem, refer to the ACC Installation and Configuration Guide, which is provided with the ACC and X.25/9000 Software Bundle and the ACC Base Software products. For information on using the utilities related to the ACC products, refer to the ACC Utilities Reference Guide. For information on installing the X.25 protocol on ACC products, refer to the X.
About ACC SNAPlus2 Link Software References 18 Chapter 1
2 Software Installation and Verification 19
Software Installation and Verification Introduction Introduction This chapter describes how to install the ACC SNAPlus2 Link Software product using the swinstall utility. NOTE Successful completion of SNA/ACC software installation relies upon PRIOR INSTALLATION OF THE ACC BASE SOFTWARE. Use swlist -l bundle to confirm prior installation. You may disregard this if you are installing SNA/ACC concurrently with the ACC Base Software product.
Software Installation and Verification Software Installation Software Installation Running Swinstall The SNA/ACC software is read from the HP-UX Application CD-ROM, in superuser mode, using the swinstall utility. The steps are shown below. Step 1. Log in to the system as “root”. Step 2. Place the media in a local or remote CD-ROM drive and mount the CD-ROM drive. For example: % mkdir /cdrom % mount /dev/dsk/c1t1d0 /cdrom Step 3. Run .
Software Installation and Verification Software Installation Step 8. Find the SDLC (ACC) item and double-click to execute the “Actions > Add Component” function. Repeat for the QLLC (X.25) item, if the status message reads Not Added (See screen illustration below). Figure 2-1 SNAplus2 Installation Using SAM Step 9. Click on “Yes” when SAM prompts you to exit, and click on “Yes” at the “Create New Kernel” prompt.
Software Installation and Verification Software Identification Software Identification • The what utility can be run on /stand/vmunix to show what version of drivers are actually generated into the system. • If you need to check version status for ACC core firmware files installed on your system, use what on /opt/acc/sys, /opt/acc/protocol, and /opt/acc/ directories. • Use the SD utility swverify to check dependency relationships, file integrity and software states if needed.
Software Installation and Verification Installation Verification Installation Verification If this is the first-time installation of an ACC card, the full procedure found in ACC Installation and Configuration Guide, Chapter 2, section “Installation Verification” can be used to verify that the ACC hardware and software have been properly installed and are functional. Otherwise skip that section and continue below.
Software Installation and Verification Installation Verification #include ”/opt/acc/cfg/ttgendefine” ttgen Configuration system-name ”SNA/ACC Interface sample ttgen input file” program-zlu 100 terminal-zlu 800 logical-term 400 physical-term 400 buffer-pool 3000000 logical-size 256 queue-Limit 200 transmit-limit 100 unack-limit 5000 port-limit 20000 E1T1-Port-Limit 100000 node-entry 1 Interface-Definition 0 Port-Definition Port 0:0 RS232 Port 0:1 RS232 Port 0:2 RS232 Port 0:3 RS232 P
Software Installation and Verification Installation Verification NOTE Versions of SNA/ACC prior to B02.40 dynamically handled the creating of terminal definitions. Versions of SNA/ACC for 3.02 and above require the user to define terminals statically in the .answ files as illustrated in the example .answ file. You must add the Term entries to your .answ file and modify them appropriately for your configuration requirements.
Software Installation and Verification Installation Verification SNA/ACC Software Verification When it is determined that the ACC Multiplexer hardware and ACC Base Software are fully operational with no problems, the peer-to-peer test procedures in this section should be run to verify that the SNA/ACC installation is correct and the SNAplus2 software can work with it. The SNAplus2 GUI, shown below (Figure 2-2), is convenient for this verification phase.
Software Installation and Verification Installation Verification Figure 2-2 Ports The xsnapadmin Screen (SNAplus2 GUI) Link Stations - 28 + Node Chapter 2
Software Installation and Verification Installation Verification Step 3. Make the following selections under “Connectivity” in the “New Port” window: Port using: ACC SDLC card SNA port name: SDLCP1 ACC SDLC card number: 0 Port number: 1 Initially active: depressed (red) Line details: Type: Leased line Link role: Primary Encoding: NRZ Duplex setting: Half duplex Step 4.
Software Installation and Verification Installation Verification Step 5. Make the following selections under “Connectivity” in the “New link station” window: Add link station to: SDLCP0 Name: SDLCL1 SNA port name: SDLCP1 Activation: By administrator LU traffic: Independent only Remote node... USHWP01.ACCP01 Contact information: Poll address: C1 SNAplus2 Over SNA/ACC Verification Use the xsnapadmin program to activate the ports and link stations: 1. Activate the node first. 2. Activate the ports. 3.
3 Using SNAplus2 via SNA/ACC 31
Using SNAplus2 via SNA/ACC Introduction Introduction For a complete description of the communication formats, refer to the documents referenced on page 17 in Chapter 1 , “About ACC SNAPlus2 Link Software,” of this manual. Data transmitted at Level 2 over an SNAplus2 link via ACC is in the SDLC format. When a QLLC link is used the data transmitted at Level 3 is framed into standard X.25 packet format.
Using SNAplus2 via SNA/ACC Checking SNAplus2 Status Checking SNAplus2 Status If the new kernel has booted successfully (Chapter 2, Section Software Installation, Step #8), the SNAplus2 software is probably running. Use the following command to check for the status of SNAplus2 on your system: /opt/sna/bin/X11/xsnapadmin NOTE Use of xsnapadmin requires Motif interface software and a bit-mapped display to run X11. Use snapadmin as an alternative if necessary.
Using SNAplus2 via SNA/ACC Checking SNAplus2 Status Figure 3-1 xsnapadmin Window 34 Chapter 3
A Files, Utilities, and Daemons This appendix provides a sample of the SNAplus2 configuration file, which can be edited to reflect different host names, etc. on different systems. Note that editing this file is equivalent to running the xsnapadmin program.
Files, Utilities, and Daemons sna_node.cfg File sna_node.cfg File /etc/opt/sna/sna_node.cfg-[define_node_config_file] major_version = 5 minor_version = 1 update_release = 1 revision_level = 18 [define_node] node_name = description = ““ node_type = LEN_NODE fqcp_name = USHWP01.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.cfg File hmod_data = ““ [define_sdlc_ls] ls_name = SDLCL1 description = ““ port_name = SDLCP1 adj_cp_name = USHWP01.
Files, Utilities, and Daemons sna_node.cfg File no_resp_timer_retry = 10 rem_busy_timer = 2000 rem_busy_timer_retry = 10 rr_timer = 0 poll_frame = XID poll_on_iframe = YES opt1 = NONE linesp = 0 hmod_data = ““ [define_directory_entry] resource_name = USHWP01. resource_type = ENCP_RESOURCE description = (Auto defined - remote node) parent_name = <0000000000000000000000000000000000> parent_type = ENCP_RESOURCE [define_directory_entry] resource_name = USHWP01.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.
Files, Utilities, and Daemons sna_node.