Security Solutions
4
Notes:
A = Requires software mirroring for data protection, using MirrorDisk/UX or VxVM mirroring between 2 separate disk enclosures
B = Requires software mirroring for data protection, using MirrorDisk/UX mirroring between 2 separate buses in the same disk enclosure, or 2 different disk enclosures
C = Supported only with the AH303A HP SC44Ge SAS Host Bus Adapter. This is a PCIe card, so it is only supported in HP Integrity Servers that support PCIe
D= Supported with HP Smart Array Controller P411 with FW 5.78b0 or later. Each host must have minimum of 2 * P411 controller in HBA mode. Dual domain not supported with P411.
Supported Entry Level Disk Arrays
ENTRY-LEVEL DISK ARRAYS
HP Products
MINIMUM SG/SGeRAC
Revision
LVM
SLVM
VxVM
3.5
CVM
3.5
VxVM 4.1
CVM 4.1
CFS 4.1
VxVM 5.0
CVM 5.0
CFS 5.0
VxVM
CVM CFS
5.0.1 SP1
VxVM
CVM CFS
5.1 SP1
Notes
P2000 G3
SG/SGeRAC A.11.18 or later on
HP-UX 11i v2,
SG/SGeRAC A.11.18 or later on
HP-UX 11i v3
NO
NO
NO
NO
NO
NO
NO
NO
NO
D
MSA2040
SG/SGeRAC A.11.20 with HP-UX
11iv3
NO
NO
NO
NO
NO
NO
NO
NO
NO
D
MSA 2312fc, MSA 2324fc
SG/SGeRAC A.11.17 or later on
HP-UX 11i v2,
SG/SGeRAC A.11.17.01 or later
on HP-UX 11i v3
NO
NO
NO
NO
NO
A, C
MSA 2312sa, MSA 2324sa
SG/SGeRAC A.11.17.01 or later
on HP-UX 11i v3
NO
NO
NO
NO
NO
B
(iSCSI Storage)
P4000 Series
SG 11.20 with PHSS_42558 or
later on HP-UX 11iv3
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
E,F
Notes:
A = Requires firmware M100R18 or later
B = Supported only with Blade Servers using the HP P700m 3 Gb SAS Controller (mezzanine) and the HP 3Gb SAS BL Switch (interconnect). The P700m must be in Pass-Thru mode (RAID mode is not supported).
Requires firmware M110R21 or later
C = Veritas 5.0.1 and 5.1 SP1 Volume Managers supported on HP-UX 11i v3 only
D = Fibre Channel only
E = iSCSI based lock LUN or Lock Disk is not supported.
F = iSCSI is supported using iSCSI Software initiator only
Supported Enterprise Disk Arrays
HP STORAGEWORKS ENTERPRISE VIRTUAL ARRAYS
HP Products
MINIMUM SG/SGeRAC
Revision
LVM
SLVM
VxVM
3.5
CVM
3.5
VxVM 4.1
CVM 4.1
CFS 4.1
VxVM 5.0
CVM 5.0
CFS 5.0
VxVM
CVM CFS
5.0.1 SP1
VxVM
CVM CFS
5.1 SP1
Notes