frupower(1M) frupower(1M)
Note: This command is a Web-Based Enterprise Management (WBEM) Client Applica-
tion. The -u option accesses the target partition using a Secure Sockets Layer (SSL)
connection. If errors are reported, check that the conditions described in the DEPEN-
DENCIES section are satisfied.
Mapping of Global Cell Numbers to Local Cell Numbers
The cabinets in a complex are numbered starting from 0. The cell slots in each cabinet are also numbered
starting from 0. Each cabinet can have a maximum of 8 cells. For example, the cells located in cabinet 0
will have the following cell numbers in global format: 0, 1, 2, 3, 4, 5, 6, 7. The cell numbers in correspond-
ing local format will be 0/0, 0/1, 0/2, 0/3, 0/4, 0/5, 0/6, 0/7.
Similarly the cells located in cabinet 1 will have the following cell numbers in global format: 8, 9, 10, 11, 12,
13, 14, 15. The cell numbers in corresponding local format will be 1/0, 1/1, 1/2, 1/3, 1/4, 1/5, 1/6, 1/7.
From the above convention the cell located in cabinet 1, slot 0 is identified in the local format as 1/0 or in
the global format as 8. The
parstatus command will display the above cell as "cab1,cell0". The cell
located in cabinet 1, slot 4 is identified in the local format as 1/4 or in the global format as 12. The
par-
status
command will display the above cell as "cab1,cell4". See parstatus(1).
RETURN VALUE
The
frupower command exits with one of the following values:
0 Successful completion.
1 Error condition occurred.
EXAMPLES
Power on the cell located in cabinet 0 slot 4 of a partition identified by the hostname GreenRiver:
frupower -o -c 0/4 -u RemoteAdmin: -h GreenRiver
RemoteAdmin must have superuser permissions on GreenRiver. The command prompts for the password.
Power off two cells located in cabinet 0 slot 4 and cabinet 0 slot 6.
frupower -f -c 0/4 -c 0/6
DEPENDENCIES
This command uses the Web-Based Enterprise Management (WBEM) product and some of its configuration
settings. If you encounter connection errors when using the
-u option, check that the following two condi-
tions are satisfied:
Use the cimconfig command (see cimconfig(1M) in the WBEM product documentation) to verify (and
correct if necessary) the setting of the following two variables:
enableRemotePrivilegedUserAccess=true
enableHttpsConnection=true
The target partition’s digital certificate has been appended to the local partitions Shared Authentication
Store. For the nPartition commands, the Shared Authentication Store is stored in the file:
/etc/opt/hp/sslshare/known_hosts.pem
. This file is used by all the clients, which use SSL
based certificates. If these clients trust a target partition, then the nPartition commands will also trust
the target partition.
Refer to the WBEM documents specified in the SEE ALSO section below for further information.
AUTHOR
frupower was developed by the Hewlett-Packard Company.
SEE ALSO
fruled(1), parstatus(1), cplxmodify(1M), parcreate(1M), parmgr(1M), parmodify(1M), parremove(1M),
parunlock(1M), partition(5).
nPartition Administrator’s Guide on http://docs.hp.com
,
HP WBEM Services for HP-UX System Administrator’s Guide on
http://docs.hp.com
,
HP WBEM Services for HP-UX 11i v2.0 on Integrity Servers Version A.01.05 Release Notes on
http://docs.hp.com.