HP-UX Reference (11i v2 07/12) - 1 User Commands N-Z (vol 2)

p
parstatus(1) parstatus(1)
cab0,cell1 Active Base 2/0/4 2/0 - no yes 2
cab0,cell2 Inactive 4/0/4 2/0 cab0,bay1,chassis3 yes yes 1
cab0,cell3 Inactive 2/0/4 2/0 - no - -
cab0,cell4 Active Core 2/0/4 2/0 cab0,bay0,chassis3 yes yes 2
cab0,cell5 Powered off 0/0/4 ? ? ? no 0
cab0,cell6 Active Core 2/0/4 2/0 cab0,bay1,chassis1 yes yes 1
cab0,cell7 Powering on 0/0/4 ? ? ? - -
Notes: * = Cell has no interleaved memory.
[Chassis]
Core Connected Par
Hardware Location Usage IO To Num
=================== ============ ==== ========== ===
cab0,bay0,chassis0 Absent - - -
cab0,bay0,chassis1 Active yes cab0,cell0 0
cab0,bay0,chassis2 Absent - - -
cab0,bay0,chassis3 Active yes cab0,cell4 2
cab0,bay1,chassis0 Absent - - -
cab0,bay1,chassis1 Active yes cab0,cell6 1
cab0,bay1,chassis2 Absent - - -
cab0,bay1,chassis3 Inactive yes cab0,cell2 1
[Partition]
Par # of # of I/O
Num Status Cells Chassis Core cell Partition Name (first 30 chars)
=== ============ ===== ======== ========== ===============================
0 Active 2 1 cab0,cell0 cup2000
1 Active 3 2 cab0,cell6 cup2006
2 Active 2 1 cab0,cell4 cup2004
WARNINGS
HP-UX 11i Version 2 is the last HP-UX release on which passing passwd for the
-u and -g options is sup-
ported. Specifying passwd on the command line will not be supported in future releases. The command
will prompt for the password.
DEPENDENCIES
This command uses the Web-Based Enterprise Management (WBEM) product and certain of its
configuration settings. If you encounter connection errors when using the
-u option, check that the follow-
ing two conditions are satisfied:
Use the cimconfig command (see cimconfig(1M) in the WBEM product documentation) to verify (and
correct if necessary) the setting of the following two variables:
enableRemotePrivilegedUserAccess=true
enableHttpsConnection=true
You must have appended the target partition’s digital certificate to the local partition’s Trust Store le.
For the nPartition commands, the Trust Store file is /var/opt/wbem/client.pem
.
Note: You must have appended the target partition’s digital certificate to the local partitions Trust
Store file. For the npartition commands, the Trust Store file is
/var/opt/wbem/client.pem
.
This file is used by the commands that come with WBEM installation. Hence, if the commands that
come with the WBEM installation trust a target partition, then npartition commands will also trust the
target partition.
Refer to the WBEM documents specified in the SEE ALSO section below for further information.
AUTHOR
parstatus was developed by the Hewlett-Packard Company.
124 Hewlett-Packard Company 5 HP-UX 11i Version 2: December 2007 Update