HP-UX Reference (11i v2 04/09) - 1 User Commands N-Z (vol 2)

p
parstatus(1) parstatus(1)
Note: This command is a Web-Based Enterprise Management (WBEM) Client Application.
The -u option accesses the target partition using a Secure Sockets Layer (SSL) connection. If
errors are reported, check that the conditions described in the DEPENDENCIES section are
satisfied.
SECURITY WARNING: Specifying the password directly on the command line may pose a
security risk in your environment. The ps(1) or other related commands can be invoked in
such a way as to display the command line of a process. In this situation, any authenticated
user on the system can potentially see the password while the process is executing. Hence, it
is highly recommended not to specify the password on the command line, and instead allow the
command to prompt for the password.
-h IPaddress|hostname
This option should only be used in combination with either the
-u or -g option.
IPaddress|hostname specifies the IP address or hostname of the target partition (
-u) or com-
plex (
-g).
-g [passwd]
Allows access to the complex specified by the
-h option. The accessed complex is then con-
sidered the target complex. Access is via the service processor’s LAN port.
The
-h option is required if this option is used.
passwd specifies the IPMI password of the service processor. If this field is omitted, the com-
mand prompts for the password.
If an error is reported when you attempt to connect using this option, check to see that IPMI
LAN access has not been disabled on the remote service processor. Access to the complex via
IPMI over LAN can be enabled or disabled by logging on to the service processor and using the
SA command from the Command Menu.
The
-u and -g options are mutually exclusive.
SECURITY WARNING: Specifying the password directly on the command line may pose a
security risk in your environment. The ps(1) or other related commands can be invoked in
such a way as to display the command line of a process. In this situation, any authenticated
user on the system can potentially see the password while the process is executing. Hence, it
is highly recommended not to specify the password on the command line, and instead allow the
command to prompt for the password.
-w Display the local partition number in a full sentence. If the -u option connects to another par-
tition, that partition number is reported instead. The -M option restricts the display to just
the partition number.
-X Display the complex attributes.
-A Only display the available resources in the complex.
-V Verbose mode. Increase the amount of information displayed.
Note: The cell IODC version field is used for PA-RISC cells only. This value will be 0xFFFF
(i.e., 65535) for Itanium(R)-based cells.
Additional information displayed with
-V includes:
For Cabinet:
* Status of each of the cabinet blower(s)
* Status of each of the I/O fan(s)
* Status of each of the bulk power supply(s)
* Status of each of the backplane power board(s)
For Partition:
* Primary, alternate and secondary boot path settings
* PDC, IODC version numbers
* Memory interleaving / local memory settings
* Cells summary info
* I/O chassis summary info
For Cell:
* Details of each cpu on the cell
HP-UX 11i Version 2: September 2004 2 Hewlett-Packard Company Section 1705