HP-UX Reference (11i v2 04/09) - 1 User Commands A-M (vol 1)

f
fruled(1) fruled(1)
NAME
fruled - flash/turn off attention LEDs (cell, cabinet and I/O chassis attention LEDs)
SYNOPSIS
fruled -c cell [-c...] [-f
|-o][-B]
[
-u username:[passwd]
-h IPaddress|hostname
|
-g [passwd] -h IPaddress|hostname ]
fruled -i I/Ochassis [-i...] [
-f|-o][-B]
[
-u username:[passwd] -h
IPaddress|hostname
|
-g [passwd] -h IPaddress|hostname ]
fruled -b cabinet [-b...] [-f
|-o]
[
-u username:[passwd]
-h IPaddress|hostname
|
-g [passwd] -h IPaddress|hostname ]
fruled -C|-I [-l cabinet ][
-l...] [-f]
[
-u username:[passwd]
-h IPaddress|hostname
|
-g [passwd] -h IPaddress|hostname ]
DESCRIPTION
The
fruled command flashes/turns off attention LEDs of cells or I/O chassis in the local complex. The
command can also be used to start flashing or stop flashing cabinet number LEDs. If either the
-u option
or the
-g option is specified, the scope of the command will be the specified target complex.
If a cell or I/O chassis attention LED is made to flash, the cabinet number LED of the cabinet that con-
tains the cell/ I/O chassis can also be made to flash by using the
-B
option. Likewise, if a cell or I/O
chassis’s LED is being turned off, the cabinet number LED can also be made to stop flashing using the
-B
option.
Note: This command does not read or display the state of any LED. Users must observe the hardware
itself to determine the state.
Please refer to the HP System Partitions Guide for a description of the partition management terms used
in this man page.
Options and Arguments
fruled recognizes the following command line options and arguments:
-f Turn off specified attention LED(s). This is the default.
-o Start flashing specified attention LED(s).
The
-o option is unavailable with -C or -I. The -f and -o options are mutually
exclusive.
-B Start or stop flashing the cabinet number LED of the cabinet that contains the cell or I/O
chassis. The -B option is only available with the -c and -i options.
-u username:[passwd]
Specifies the required authorization to access a partition other than the local partition
(but can also be used as a loopback access to the local partition). The complex to be
modified is the one in which this target partition resides.
The
-h option is required if this option is used.
username specifies a configured user name on the target partition.
passwd specifies the password associated with the username. If this field is empty, the
command prompts for the password.
Note: This command is a Web-Based Enterprise Management (WBEM) Client Applica-
tion. The
-u option accesses the target partition using a Secure Sockets Layer (SSL) con-
nection. If errors are reported, check that the conditions described in the DEPENDEN-
CIES section are satisfied.
SECURITY WARNING: Specifying the password directly on the command line may pose
a security risk in your environment. The ps(1) or other related commands can be
invoked in such a way as to display the command line of a process. In this situation, any
authenticated user on the system can potentially see the password while the process is
executing. Hence, it is highly recommended not to specify the password on the command
HP-UX 11i Version 2: September 2004 − 1 − Hewlett-Packard Company Section 1−−315