HP-UX Reference (11i v2 03/08) - 1M System Administration Commands A-M (vol 3)

f
fcmsutil(1M) fcmsutil(1M)
NAME
fcmsutil - Fibre Channel Mass Storage Utility Command for the TACHYON TL A5158A and TACHYON
XL2 A6795A Fibre Channel Host Bus Adapters.
SYNOPSIS
/opt/fcms/bin/fcmsutil
device_file
/opt/fcms/bin/fcmsutil
device_file
vpd
/opt/fcms/bin/fcmsutil
device_file
echo remote-N-Port-ID [data-size ][count]
/opt/fcms/bin/fcmsutil
device_file
rls remote-N-Port-ID
/opt/fcms/bin/fcmsutil
device_file
test remote-N-Port-ID [data-size ][count]
/opt/fcms/bin/fcmsutil
device_file
read offset [pci]
/opt/fcms/bin/fcmsutil
device_file
write offset value [pci]
/opt/fcms/bin/fcmsutil
device_file [
-f] lb [plm|crpat|cjtpat ]
/opt/fcms/bin/fcmsutil
device_file
get local|fabric
/opt/fcms/bin/fcmsutil
device_file
get remote {all|remote-N-Port-ID}
/opt/fcms/bin/fcmsutil
device_file get_lgn N-Port-ID
/opt/fcms/bin/fcmsutil
device_file reset
/opt/fcms/bin/fcmsutil
device_file [-f] bdr target-device_file
/opt/fcms/bin/fcmsutil
device_file read_cr
/opt/fcms/bin/fcmsutil
device_file stat [-s]
/opt/fcms/bin/fcmsutil
device_file clear_stat
/opt/fcms/bin/fcmsutil
device_file nsstat
/opt/fcms/bin/fcmsutil
device_file clear_nsstat
/opt/fcms/bin/fcmsutil
device_file devstat {all|remote-N-Port-ID}
/opt/fcms/bin/fcmsutil
device_file clear_devstat {all|remote-N-Port-ID}
/opt/fcms/bin/fcmsutil
device_file replace_dsk remote-N-Port-ID
/opt/fcms/bin/fcmsutil
device_file [-f] disable
/opt/fcms/bin/fcmsutil
device_file enable
/opt/fcms/bin/fcmsutil
device_file [-k] ns_query_ports
Note: The remote-N-port-ID can be substituted with
-l loop_id (in Private Loop), or -w wwn
for all options that take remote-N-port-ID as an argument. The
devstat all option displays
the loop_id (in Private Loop) and the nport_id (in Fabric) along with the statistics for all N_Ports
the initiator was able to communicate with.
DESCRIPTION
The
fcmsutil command is a diagnostic tool to be used for the TACHYON TL A5158A and TACHYON
XL2 A6795A Fibre Channel Host Bus Adapters. This command provides the ability to perform Fibre
Channel Test and Echo functionality, read the card’s registers, etc. This command requires the use of a
device file to indicate the interface over which the requested command needs to be performed.
The options that are available only for the TACHYON XL2 A6795A are indicated by a "XL" in the descrip-
tion for the option.
All other options (which do not have the "XL" indication) are supported by both HBAs.
fcmsutil can be used only by users who have an effective user ID of 0. Some of the options require
detailed knowledge of the device specific adapter.
Options
fcmsutil recognizes the following options as indicated in SYNOPSIS. All keywords are case-insensitive
and are position dependent.
HP-UX 11i Version 2: August 2003 1 Hewlett-Packard Company Section 1M181