HP-UX Reference (11i v1 05/09) - 1M System Administration Commands A-M (vol 3)

a
arraymgr(1M) arraymgr(1M)
arraymgr: Unknown argument
An invalid argument was specified. Check command usage.
arraymgr: No such file or directory
The specified array-id does not exist or does not identify a disk array LUN that is communicating with
the system. Verify the correct array-id with ioscan(1M).
arraymgr: Error in command execution, <Additional Error Info>:
<Error Info Decode>
The command failed due to a device error, an internal error, or a system error. The More Error Info
and Error Info Decode fields will hold specifics about the failure and its cause.
arraymgr: The array did not start up following the reset.
The disk array has been reset, but it did not start up again. Check the control panel for possible
hardware failure.
arraymgr: The array is not shutdown, no restart performed.
An attempt was made to restart a disk array that was not shutdown.
arraymgr: The array did not restart in the expected time.
Following a restart command, the disk array took too long to come back on line.
arraymgr: The array is already shutdown.
An attempt was made to shutdown a disk array that was already shutdown.
arraymgr: The specified controller is not physically installed.
An attempt was made to perform an operation on a controller that is not installed in the disk array.
arraymgr: The specified controller is already active.
An attempt was made to make the currently active controller active again.
arraymgr: Active Spare Desired flag has been set, however the
array is reporting the Active Spare is not available.
The Active Spare feature has been enabled, but the disk array does not have enough unallocated capa-
city to create the Active Spare. Add another disk or delete an existing LUN to increase the amount of
unallocated capacity so the Active Spare can be created.
arraymgr: Array was just powered-on or reset.
The command failed because the disk array has been powered-on or reset. Reissue the command and
it should succeed.
EXAMPLES
Shutdown the disk array identified by device file /dev/rdsk/c2t0d0
:
arraymgr -s shut /dev/rdsk/c2t0d0
Restart disk array serial number 00786b5c0000 :
arraymgr -s start 00786b5c0000
Set Y as the active controller on disk array serial number 00786b5c0000 :
arraymgr -C Y 00786b5c0000
Assign an alias to the disk array identified by device file /dev/rdsk/c2t0d0. Use an alias that
identifies the rack the disk array is installed in (
51 for this example), and the shelf position the disk array
is on (03 for this example):
arraymgr -D RACK_51_03 /dev/rdsk/c2t0d0
Set the data resiliency protection level to the highest level of protection on the disk array identified by alias
AUTORAID2.
arraymgr -J Secure AUTORAID2
DEPENDENCIES
ARMServer must be running to execute this command. See ARMServer(1M).
SECURITY CONFIGURATION
This command is modified for all security configurations.
Section 1M66 Hewlett-Packard Company 4 HP-UX 11i Version 1: September 2005