HP-UX Reference (11i v1 05/09) - 1M System Administration Commands A-M (vol 3)
a
arraydsp(1M) arraydsp(1M)
4 = Controller X DRAM
5 = Controller X NVRAM
6 = Controller Y DRAM
7 = Controller Y DRAM
8 = Controller X batteries
9 = Controller Y batteries
Because there may be multiple components of type "<CompID>", the "<nn>" field further
identifies the component. "<nn>" will always be 0 for a "<CompID>" = CONTROLLER.
The "<CntrlrID>" identifies the associated controller. If no association exists for this component
with a controller, this field will be empty. "<CompState>" and "<BattState>" indicate the state
of the component or battery, respectively.
-i The following single-line output includes a separate field (xxxxxxxxxx) for each disk array
identified:
I:xxxxxxxxxx:xxxxxxxxxx
The leading "I" is literal to identify this as an Identify record.
-l L:HP:ProductID:LunNumber:Present:MaxBlockAddr:
BlockLength:<arraySN>:<Alias>
The leading "L" is literal to identify this as a LUN record. "Present" is a Boolean, TRUE if the
LUN is configured, FALSE otherwise. If a LUN is not specified, the above will be displayed for
all LUNs.
-m PM:HP:ProductID:<requestedStime>:
<requestedEtime>:<actualStime>:<actualEtime>:<interval>:<arraySN>
:<PerfMetricId>:<nn>:<nn>: ...
:<PerfMetricId>:<nn>:<nn>: ...
:<PerfMetricId>:<nn>:<nn>: ...
The leading "PM" is literal to identify this as a PERFORMANCE METRIC record.
-r PR:HP:ProductID:<stime>:<etime>:
<Recommendation1>:<Recommendation2>:...
The leading "PR" is literal to identify this as a PERFORMANCE RECOMMENDATIONS record.
-s S:HP:ProductID:VolSetPartition:FmtPatternFill:
AutoRebuild:AutoInclude:Parity:SDTR:WDTR:TermPwr:UnitAtn:
ActiveSpare:LogFullWarn:WrtCache:RdCache:RebuildPri:
CapDepThresh:WrtWrkSetInt:SubsysTypeID:
Language:CntXaddr:CntYaddr:Rebuilding:RebuildPercentage:
Balancing:Optimizing:<ArrayState>:<WarnInd>:DRR:<ArraySN>:
LUNCreateLimit:MaxLUNCreateLimit:SecContOffline:VeryEarlyBusy
QueueFullThreshold:MaxQueueFullThreshold:
DisableSingleControllerWarning:LockWriteCacheOn:
DisableNVRAMonWCEfalse:DisableNVRAMonSingleController:
DisableNVRAMonUPSabsent:<ForceUnitAccessResponse>:
DisableReadHits:RecoveryInProgress:<RecoveryProgress>:
<ResiliencyThreshold>
The leading "S" is literal to identify this as an ARRAY STATE record. "<WarningState>" will be
a hexadecimal number representing the "Warning Indications" field returned by the "Check
Array State" command, which is described in the "HP XLR1200 Advanced Disk Array SCSI
Interface Specification" (5010-3128).
-v V:HP:ProductID:Raid1Blocks:Raid1BlockSize:<arraySN>
The leading "V" is literal to identify this as a VIRTUAL record.
DEPENDENCIES
ARMServer must be running to execute this command. See ARMServer(1M).
SECURITY CONFIGURATION
This command is modified for all security configurations.
Section 1M−−54 Hewlett-Packard Company − 5 − HP-UX 11i Version 1: September 2005