HP-UX Reference (11i v1 05/09) - 1M System Administration Commands A-M (vol 3)
a
amdsp(1M) amdsp(1M)
The specified ArrayID does not exist or does not identify a device that is communicating with the sys-
tem. Verify the array exists and is operational.
amdsp: The specified controller is not physically installed.
A controller-specific command was issued to a non-existent or inaccessible controller.
amdsp: The specified LUN does not exist in this array.
The specified LUN does not exist.
amdsp: No array controllers installed
The software was unable to identify an installed controller in the array. This may be due to controller
failure, or cabling problems. Correct the problem and re-issue the command.
amdsp: No controller hardware path was found for the given device file
A controller-specific command was issued to a non-existent or inaccessible controller.
amdsp: Error in command execution, <Additional Error Info>:
<Error Info Decode>
The command failed due to a device error, an internal error, or a system error. The Additional Error
Info and Error Info Decode fields will hold specifics about the failure and its cause.
EXAMPLES
Display general information about disk array RACK_51:
amdsp RACK_51
Display information for LUN 2 on disk array named RACK_51:
amdsp -l 2 RACK_51
Display information for all LUNs on disk array RACK_51:
amdsp -l RACK_51
Display information for all disks installed in disk array named RACK_51:
amdsp -d RACK_51
List the serial numbers of all of the disk arrays recognized by the host:
amdsp -i
RAW OUTPUT FORMAT
The contents of the raw output text string for each display option are listed here. Note that the raw output
for the -a option comprises the individual strings displayed by the -l,-d,-c,
-s,-g,-A, -r, and -h
options. For clarification when evaluating Boolean expressions, TRUE=1 and FALSE=0.
OPTION RAW OUTPUT DESCRIPTION
none D:VendorID:ProductID:ArrayID:ServerName:ArrayType:
MfgProdCode:PhysCapacity:LUNCapacity:
HotSpareCapacity:UnallocatedCapacity:ArrayState:
ArrayAlias
The leading D is literal to identify this as a DEFAULT record.
All capacities are in GB where 1GB=1024ˆ3 bytes , except LUN capacity, which is always in
MB in raw output mode, where 1MB=1024ˆ2 bytes .
-c The following is output for each disk array controller:
C:Subsystem:CntrlrID:CompState:CntrlrMode:Quiesced:VendorID:
ModelNum:SerNumber:FWRevision:BootRevision:HPRev:LoopID:ALPA:
PreferredALPA:CntrlrDate:CntrlrTime:CacheBattAge:ArrayID:NVRAMChecksum
The following is output for each disk enclosure controller:
C:Subsystem:CntrlrID:CompState:CntrlrMode:Quiesced:VendorID:
ModelNum:SerNumber:FWRevision:EncSerNum:EncID:SubsysChannel:
SubsysScsiID:ThumbwheelSetting:CntrlrDate:CntrlrTime:CacheBattAge:ArrayID
The leading C is literal to identify this as a CONTROLLER record.
HP-UX 11i Version 1: September 2005 − 3 − Hewlett-Packard Company Section 1M−−27