HP-UX Reference (11i v1 05/09) - 1M System Administration Commands A-M (vol 3)
a
amdload(1M) amdload(1M)
amdload -?
An error in command syntax has occurred. Re-enter the command with all necessary arguments.
amdload: Arg out of range
One of the arguments has exceeded its maximum or minimum size, or is incorrect in form. Check the
size and form of each argument.
amdload: The <ArrayID> entered does not identify a known, supported
array
The specified ArrayID does not exist or does not identify a device that is communicating with the sys-
tem. Verify the array exists and is operational.
amdload: Firmware download has been aborted.
Disk <disk> does not exist in the subsystem.
The specified disk does not exist in the subsystem. Re-enter the list of disks, making sure all disks
are physically present. A similar message will appear for channels that do not exist.
amdload: Firmware download has been aborted.
There is more than one type of disk mechanism among
the disks selected for update.
Any particular firmware file is only valid for one type of disk mechanism. This message will appear if
the disks specified for update are of more than one mechanism type. Re-enter the list of disks, only
including disks of one mechanism type.
amdload: The disk <disk> was repeated in your list.
Re-enter the command, listing each item once.
This message will appear if a disk or channel is repeated in the input list. Be sure to list each item
once.
amdload: Firmware download has been aborted.
LUN <lun> is not in an Optimal state. Wait until all LUNs are in
an Optimal state before attempting further firmware downloads.
LUNs must be in an Optimal state before attempting disk or array controller downloads. This mes-
sage will appear if any LUNs are not Optimal prior to a download, or if a LUN enters a non-Optimal
state between disk downloads.
amdload: Error in command execution, <Additional Error Info>:
<Error Info Decode>
The command failed due to a device error, an internal error, or a system error. The Additional Error
Info and Error Info Decode fields will hold specifics about the failure and its cause.
EXAMPLES
Download new firmware from file
coderev2.1 to both disk array controllers on disk array RACK_51:
amdload -C all coderev2.1 RACK_51
Download new firmware from file diskrev3.2 to the specified disks (channel 6, SCSI ID 2 and channel
6, SCSI ID 4) in disk array RACK_51:
amdload -D 6:2,6:4 diskrev3.2 RACK_51
Download new firmware from file bccrev14 to the BCC controllers on all the disk systems on disk array
RACK_51:
amdload -S all bccrev14 RACK_51
DEPENDENCIES
AM60Srvr must be running to execute this command. See AM60Srvr(1M).
AUTHOR
amdload was developed by HP.
SEE ALSO
amdsp(1M), amcfg(1M), amutil(1M), amlog(1M), ammgr(1M), AM60Srvr(1M).
Section 1M−−24 Hewlett-Packard Company − 3 − HP-UX 11i Version 1: September 2005