hotplugd(1M) hotplugd(1M)
gives the time at which the event was received.
Wait for the attention button processing on a slot to complete before pressing the attention button
again on that slot.
#oprnNum - slot( slotId ) - Setting power led to PWR_RAIL mode failed,
errno =
errMsg
The power LED could not be set to
PWR_RAIL mode for the given slotId. errMsg gives the reason for
the error.
#oprnNum - slot( slotId ) - Setting power led to PWR_RAIL mode failed,
olar_error_no =
olarErrMsg
The power LED could not be set to
PWR_RAIL mode for the given slotId. olarErrMsg gives the rea-
son for the error.
Usage : hotplugd <logFileName> <append|trunc>
The hotplugd program was invoked with an invalid set of parameters.
hotplugd : fork() failed, errno = errMsg
hotplugd could not fork itself. errMsg gives the reason for the error.
hotplugd : Could not open log file : logFile, errno = errMsg
hotplugd could not open the given logFile in write mode. errMsg gives the reason for the error.
hotplugd : Could not get lock on file : logFile, errno = errMsg
hotplugd could not get the lock on the logFile. errMsg gives the reason for the error.
It could be because another instance of hotplugd is running.
FILES
/etc/rc.config.d/pci_olar
Configuration file for PCI I/O OLAR operations.
/sbin/init.d/pci_olar
Startup script, used to start the daemon.
/var/adm/hotplugd.log
Installed default name of file where the daemon logs messages. See the DIAGNOSTICS
section and the Daemon Startup subsection for details.
/var/adm/syslog/syslog.log
System log file. See the DIAGNOSTICS section for details.
SEE ALSO
rad(1M), syslogd(1M), errno(2), fcntl(2), ioctl(2).
Interface Card OL* Support Guide and Interface Card OL* Support Matrix documents available at the
http://docs.hp.com
website.