HP-UX Reference (11i v1 05/09) - 1 User Commands A-M (vol 1)

f
fruled(1) fruled(1)
parstatus(1) command will display the above cell as "cab1,cell4".
RETURN VALUE
The
fruled command exits with one of the following values:
0 Successful completion.
1 Error condition occurred.
2 No LED associated with specified object.
EXAMPLES
Flash the attention LED of the cell located in cabinet 0 slot 4 and also flash the attention LED of the
cabinet in which it is contained.
fruled -o -B -c 0/4
Turn off the attention LEDs of 2 cells located in cabinet 0, slot 4 and cabinet 0, slot 6.
fruled -f -c 0/4 -c 0/6
DEPENDENCIES
This command uses the Web-Based Enterprise Management (WBEM) product and certain of its
configuration settings. If you encounter connection errors when using the
-u option, check that the follow-
ing two conditions are satisfied:
Use the cimconfig(1M) command to verify (and correct if necessary) the setting of the following two vari-
ables:
enableRemotePrivilegedUserAccess=true
enableHttpsConnection=true
You must have appended the target partition’s digital certificate to the local partition’s Trust Store file.
For the nPartition commands, the Trust Store file is
/opt/nparcmds/nparcmds.pem
.
Refer to the WBEM documents specified in the SEE ALSO section below for further information.
AUTHOR
fruled was developed by the Hewlett-Packard Company.
FILES
/usr/sbin/ The partition commands under this directory do not provide remote management
feature.
/usr/lib/npar/ The partition commands under this directory provide remote management feature.
These commands use the nPartition Provider product.
/opt/nparprovider/lib/installed
The presence of this file indicates that nPartition Provider is installed.
SEE ALSO
parstatus(1), partition(1), frupower(1M), parcreate(1M), parmgr(1M), parmodify(1M), parremove(1M),
parunlock(1M)
HP System Partitions Guide on http://docs.hp.com,
HP WBEM Services for HP-UX System Administrator’s Guide on
http://docs.hp.com
,
HP WBEM Services for HP-UX 11i v2.0 on Integrity Servers Version A.01.05 Release Notes on
http://docs.hp.com.
HP-UX 11i Version 1: September 2005 3 Hewlett-Packard Company Section 1299