ups_mond(1M) ups_mond(1M)
(Series 800 Only)
permission denied; must be superuser.
exiting; unable to lock process in memory: <
errno>.
aborted, configfile <
configfilename> open received error: <errno>.
aborted, configfile <
configfilename> fseek error: <errno>.
aborted, malloc error: <
errno>.
terminated by signal <
decimal value of signal>.
Messages for which shutdown might be run (depends on UPS configuration):
UPS <tty special file name> AC POWER FAILURE - running on UPS battery.
If power is not returned within previously configured time period,
your system will automatically go to graceful shutdown.
If power is not returned within previously configured time period,
your system will automatically go to graceful shutdown. System will
not come back up after shutdown.
Messages for which reboot might be run (depends on UPS configuration):
UPS <tty special file name> battery low.
UPS <
tty special file name> no output - either switch setting wrong on UPS
or bad UPS.
UPS <
tty special file name> failed - requires repair.
UPS <
tty special file name> current overload; UPS turned itself off - either
UPS bad or too many devices connected.
UPS <
tty special file name> ambient temperature too high; UPS turned itself
off - reduce heat in area.
UPS <
tty special file name> output voltage too high; UPS turned itself off -
requires repair.
UPS <
tty special file name> output voltage too low; UPS turned itself off -
requires repair.
cannot exec shutdown due to <
errno>.
The above messages are followed by the following message:
reboot -halt invoked due to UPS error cited in previous syslog mes-
sage.
Messages that are only logged (no shutdown/reboot action is taken):
warning - no upstty: UPS’s found in configfile <configfilename>; daemon
running for no purpose.
warning - shutdown delay or shutdown timeout parameter in configfile
<
configfilename> missing or not greater than zero; using default.
UPS <
tty special file name> in bypass-mode; no AC Power-loss protection.
UPS <
tty special file name> interrupted, but read of ups status failed -
possible UPS hardware problem.
upstty <
tty special file name> failed open: <errno>; ignoring that tty and
continuing.
UPS <
tty special file name> ioctl(TCGETA) failed: <errno>; ignoring that UPS.
UPS <
tty special file name> ioctl(TCSETAF) failed <errno>; ignoring that UPS.
UPS <
tty special file name> line too noisy; ignoring that UPS.
UPS <
tty special file name> could not enable; loss of power would not be
detectable.
UPS <
tty special file name> read failed: <errno>; Uninterruptible Power Sup-
ply has not been connected correctly; loss of power would not be
HP-UX Release 11i: December 2000 − 2 − Section 1M−−979