HP-UX Reference (11i v1 00/12) - 1M System Administration Commands A-M (vol 3)
__________________________________________________________________________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________________________________________________________________
STANDARD Printed by: Nora Chuang [nchuang] STANDARD
/build/1111/BRICK/man1m/!!!intro.1m
________________________________________________________________
___ ___
a
amdsp(1M) amdsp(1M)
amdsp: Array just powered-on or reset.
The array was just powered-on or was reset. Reissue the command.
amdsp: The specified controller is not physically installed.
A controller-specific command was issued to a non-existent or inaccessible controller.
amdsp: The specified LUN does not exist in this array.
The specified LUN does not exist.
amdsp: No array controllers installed
The software was unable to identify an installedcontroller in the array. This may be due to controller
failure, or cabling problems. Correct the problem and re-issue the command.
amdsp: No controller hardware path was found for the given device file
A controller-specific command was issued to a non-existent or inaccessible controller.
amdsp: Error in command execution, <Additional Error Info>:
<Error Info Decode>
The command failed due to a device error, an internal error, or a system error. The Additional Error
Info and Error Info Decode fields will hold specifics about the failure and its cause.
EXAMPLES
Display general information about disk array RACK_51:
amdsp RACK_51
Display information for LUN 2 on disk array named RACK_51:
amdsp -l 2 RACK_51
Display information for all LUNs on disk array RACK_51:
amdsp -l RACK_51
Display information for all disks installedin disk array named RACK_51:
amdsp -d RACK_51
List the serial numbers of all of the disk arrays recognized by the host:
amdsp -i
RAW OUTPUT FORMAT
The contents of the raw output text string for each display option are listed here. Note that the raw output
for the -a option comprises the individual strings displayed by the -l,-d,-c, -s
,-g,-A, and -h options.
For clarification when evaluating Boolean expressions,
TRUE=1 and FALSE=0.
OPTION RAW OUTPUT DESCRIPTION
none D:VendorID:ProductID:ArrayID:ServerName:ArrayType:
MfgProdCode:PhysCapacity:LUNCapacity:
HotSpareCapacity:UnallocatedCapacity:<ArrayState>:
<WarnInd>:<ArrayAlias>
The leading D is literal to identify this as a DEFAULT record.
All capacities are in GB where 1GB=1024ˆ3 , except LUN capacity, which is always in MB in
raw output mode, where 1MB=1024ˆ2 .
-c The following is output for each disk array controller:
C:Subsystem:CntrlrID:CompState:CntrlrMode:Quiesced:VendorID:
ModelNum:SerNumber:FWRevision:BootRevision:HPRev:LoopID:ALPA:
PreferredALPA:CntrlrDate:CntrlrTime:CacheBattAge:ArrayID:NVRAMChecksum
The following is output for each disk enclosure controller:
C:Subsystem:CntrlrID:CompState:CntrlrMode:Quiesced:VendorID:
ModelNum:SerNumber:FWRevision:EncSerNum:EncID:SubsysChannel:
SubsysScsiID:ThumbwheelSetting:CntrlrDate:CntrlrTime:CacheBattAge:ArrayID
The leading C is literal to identify this as a CONTROLLER record.
HP-UX Release 11i: December 2000 − 3 − Section 1M−−27
___
___