HP-UX Reference (11i v1 00/12) - 1M System Administration Commands A-M (vol 3)

__________________________________________________________________________________________________________________________________________________________________________________________________
__________________________________________________________________________________________________________________________________________________________________________________________________
STANDARD Printed by: Nora Chuang [nchuang] STANDARD
/build/1111/BRICK/man1m/!!!intro.1m
________________________________________________________________
___ ___
f
fcmsutil(1M) fcmsutil(1M)
A Fibre Channel Test packet of the specified size is sent to the remote node. The command
completes successfully and immediately on sending all the test packets.
Note: Packet size specified must be a multiple of 4.
read This option requires one parameter, the offset of the register to read from. The offset can be
specified in either hex or in decimal format. The offset specified is an offset from the base of
the Memory Map. The user of this command is therefore expected to have internal
knowledge of the chip. Reading from the Tachyon frame manager status register (0x01c8)
is restricted.
An optional second argument (pci) can be specified for the TACHYON TL A5158A card, to
read from the PCI config space. If no second argument is specified, it reads from the chip
register space.
write This option requires two parameters, the offset of the register to write to and the value to
be written.
An optional third argument (pci) can be specified for the TACHYON TL A5158A card, to
write into the PCI config space. If no third argument is specified, it writes into the chip
register space.
lb WARNING: This is a DESTRUCTIVE test and DATA LOSS during the execution of this
test may occur. The -f option can be used to suppress the warning message displayed by
the TACHYON TL A5158A card.
This option requires one parameter, tachyon or plm. The TACHYON TL A5158A card
supports only the plm option. An optional third argument (count) can be specified for the
number of loopback packets to be sent. If the count option is not specified, one packet will
be sent. The count option is supported only by the TACHYON TL A5158A card.
This command performs an internal loopback test when the tachyon option is specified
and performs an external loopback test when plm option is specified. The fibre channel
chip is programmed in either internal loopback mode (tachyon) or external loopback
mode (plm) based on the parameter specified. Here plm refers to physical link module or
gigabit link module. The self test then involves sending a packet and receiving back the
packet within the adapter and checking its integrity. Since this self test is at the adapter
level, no packet goes on the fibre link.
get The get option is used to obtain Fibre Channel login parameters of either the local port,
the
fabric port or of a remote port. The TACHYON TL A5158A card does not support
the local option. If the all argument is specified for the remote option, login parame-
ters and current states of all N_ports that the initiator is aware of, are displayed. The
all
option is supported only by the TACHYON TL A5158A card.
get_lgn (T) The get_lgn option is used to obtain detailed information maintained in the login block
associated with each N_Port that this N_Port has communicated with. The remote-AL_PA is
a required parameter for this option. This option is not supported by the TACHYON TL
A5158A card.
reset resets the fibre channel card. This is a destructive test and communication to all nodes will
be terminated till the reset process is completed. This option only results in a soft reset for
the TACHYON TL A5158A card and does not result in termination of communication.
bdr (TL) WARNING: This is a DESTRUCTIVE test. The -f
option can be used to suppress the
warning message displayed by the TACHYON TL A5158A card.
This option resets the target, clearing all commands, without doing any checks. This option
is supported only by the TACHYON TL A5158A card.
read_cr This option can be used to read all of the readable registers on the card and format the
detailed information.
lgninfo_all (T)
This option is used to obtain a comprehensive list of nodes to which a successful login has
been established. This option is not supported by the TACHYON TL A5158A card.
stat This option is used to obtain detailed statistics maintained by the driver. An optional argu-
ment (-s) can be specified for the TACHYON TL A5158A card, to obtain a shortened ver-
sion of the statistics maintained by the driver.
HP-UX Release 11i: December 2000 3 Section 1M221
___
___