HP PRM Version C.03.02.xx Release Notes for HP-UX 11i v1, HP-UX 11i v2, and HP-UX 11i v3

PRM Release Notes
Known problems and workarounds
Chapter 1 19
Application hangs in FSS group with capping enabled
Issue
On HP-UX 11i v2 (B.11.23), an application inside an FSS group may hang
when running in a single-processor virtual partition, nPartition, or system if
CPU capping is enabled.
Workaround
Install patch PHKL_33052.
Inconsistent inheritance
Issue
If a process placed in a PRM group via prmrun, prmmove, or a record spawns
child processes, those child processes remain in the same PRM group as the
parent. However, if the child process matches a Unix group record, the
process is moved to the corresponding PRM group.
Workaround
Consider using user records instead of Unix group records to maintain
inheritance.
SMH interface limit on application name length
Issue
PRMs interface in System Management Homepage limits the name of an
application to 40 characters.
Workaround
Use a text editor to add application names of more than 40 characters to the
configuration file.
xprm cannot edit invalid configuration files
Issue
xprm cannot edit invalid configuration files.
Workaround
Use prmconfig -s to locate problems in the file. Fix the file in a text editor.