Online Diagnostics (EMS and STM) Administrator's Guide March 2012
The Fibre Channel Arbitrated Loop Hub Monitor (dm_fc_hub) supports the following models of
the Fibre Channel Arbitrated Loop (FC-AL) hubs.
• A3724A
• A4839A
The FC-AL Hub monitor requires the following device firmware revisions:
• Device Agent Firmware revision 2.14 or later
• Hub Controller Firmware revision 3.06 or later
Firmware and installation instructions are available at:
http://www.hp.com/go/softwaredepot
Before using the hub monitor, edit the monitor configuration file
(/var/stm/config/tools/monitor/dm_fc_hub.cfg) to specify the hubs to be monitored.
The Fibre Channel Switch Monitor (dm_fc_sw) supports the following models of Fibre Channel
Switch:
• A5223A
• A5224A
• A5625A
• A7347A
Before using the switch monitor, edit the monitor configuration file
(/var/stm/config/tools/monitor/dm_fc_sw.cfg) to specify the switches to be monitored.
The PA-RISC Memory Monitor (dm_memory) supports all system memory on PA-RISC-based systems.
The Itanium Memory Monitor (memory_ia64) supports all system memory on Itanium-based
systems.
Table 2-5 lists the system requirements.
Table 7 System
Special RequirementsModel/Product NumberProduct
This requirement is applicable
to HP-UX 11i v1 only. The
Superdome S-ClassSystem chassis logs: Supported by Chassis Code Monitor
(dm_chassis). The monitor reads all the chassis logs in
the /var/stm/logs/os/ccbootlog file.
chassis code logging daemon
(cclogd) must be up and
running.
NoneNACore hardware (hardware within the System Processor
Unit cabinet), for example, resources associated with
intake temperature. On some systems, other hardware
resources, such as power supplies, are monitored:
Supported by Core Hardware Monitor (dm_core_hw)
NoneNACorrected Machine Checks (CMCs) experienced by
Itanium-based systems: Supported by CMC Monitor
(cmc_em)
HP-UX 11i v2 or later.NACorrected Platform Error (CPE) Monitor for all
Itanium-based systems: Supported by Itanium Core
Hardware Monitor (cpe_em)
NoneNACore hardware on PA-RISC and Itanium-based systems,
for example, resources associated with temperature or
power supply: Supported by Itanium Core Hardware
Monitor (ia64_corehw)
Software and Hardware Requirements 17