EMS Release Notes for HP-UX 11i v3 March 2011 Release

Not applicable
Memory (dm_memory)
Not applicable
Memory IA64 (memory_ia64)
Not applicable
Memory Monitor -- Hitachi (ipfmemory_hitachi)
Not applicable
MSA1000/MSA30 Storage Disk Array Monitor (msamon)
Not applicable
MSA 60 and MSA 70 SAS Enclosure Monitor (msamon_sas)
Not applicable
Peripheral Status Monitor (psmmon)
Not applicable
RAID Adapter Monitor (dm_raid_adapter)
Not applicable
Remote Monitor (RemoteMonitor)
Not applicable
Serial-Attached SCSI (SAS) Mass Storage Adapter monitor
(dm_sas_adapter)
Not applicable
SCSI Disk Monitor (scsi_disk)
Not applicable
System Status Monitor (sysstat_em)
Not applicable
UPS Monitor (dm_ups)
Not applicable
Changes to Configuration Files
Not applicable
Changes to Monitoring Request Manager
Not applicable
Known Problems
The severity of disk_em Event #102676 should be SERIOUS. But the
default_disk_em.clcfg displays a different severity. The severity should be
changed manually from CRITICAL to SERIOUS by entering the following
command:
# vi /var/stm/config/tools/monitor/default_disk_em.clcfg
EQ:102676:CRITICAL:TRUE:1440:ANY:1:NONE:NO_OP:NO_OP:NONE
=>
EQ:102676:SERIOUS:TRUE:1440:ANY:1:NONE:NO_OP:NO_OP:NONE
Release Notes for EMS Hardware Monitors B.11.31.16.02 on HP-UX 11i v3 (March 2011) 5