Configuring Monitors with the EMS GUI
Select this option to send an event periodically, regardless of the value.
Define a polling interval that is appropriate to your system performance and reaction time
needs. See next step.
3. Specify a polling interval for how often the monitor checks the resource and reports the value.
This applies only to non-asynchronous monitors.
4. Specify how often the monitor should check and send notification about the resource:
the Initial option immediately checks and returns the resource value regardless of threshold
conditions
the Repeat option checks and returns the resource value at each polling interval if threshold
conditions have been met.
the Return option checks and returns the resource value after a threshold condition has been
resolved and the threshold condition is no longer true.
5. Specify the notification protocols. Notification protocols include such methods as:
opcmsg (IT/O), by severity or map severity from values listed
TCP or UDP
SNMP trap, by severity or map severity from values listed
email
console
syslog
textlog
Top of Page
/ http://www.hp.com/go/hpux-diagnostics-docs