Error Detection
The following example shows an error detected by the test module cpudiag. In the example,
ERRPRINT is on, ERRPAUSE is on, and cpudiag implements a command that dumps the state
of the general registers (REGISTER). This example begins with only ODE loaded. Notice the
changes in the command prompt:
Example 4-3 Error Detection
ODE> run cpudiag
***********************************************************************
****** ******
****** CPUDIAG ******
****** ******
****** (C) Copyright Hewlett-Packard Co 2006 ******
****** All Rights Reserved ******
****** ******
****** This program may only be used by HP support personnel and ******
****** those customers with the appropriate Class license or ******
****** Node license for systems specified by the license. HP ******
****** shall not be liable for any damages resulting from misuse ******
****** or unauthorized use of this program. This program ******
****** remains the property of HP. ******
****** ******
****** Version XX.XX.XX ******
****** ******
***********************************************************************
Type HELP for command information.
STARTING EXECUTION OF CPUDIAG
SECTION 001
ERROR 002 DETECTED IN SECTION 001 WHILE TESTING THE CPU
General register 8 was 0x555555a5 should be 0x55555555.
CPUDIAG PAUSED> proc
CPUDIAG PAUSED> resume
SECTION 002
SECTION 003
CPUDIAG DETECTED 1 HARDWARE ERROR
END OF LOOP 1.
RUN COMPLETED
ODE>
Determining the Tools Supported by the Platform
Some ODE tools cannot be used on all platforms. Attempting to use an unsupported tool will
generate an error message. For example:
24 Performing Common ODE Tasks