sautil.1m (2011 03)

s
sautil(1M) sautil(1M)
3) Cache data loss has occurred.
4) Array expansion was aborted.
5) The logical drive is temporarily disabled because another logical drive on the con-
troller had a missing disk at power-up.
USING INTERIM RECOVERY MODE
Also known as "degraded" state. A physical disk in a fault tolerant logical drive has
failed. For RAID 1, 1+0 or 5, data loss may result if a second disk should fail. For RAID
ADG, data loss may result if two additional disks should fail.
READY FOR RECOVERY OPERATION
A replacement disk is present, but rebuild hasnt started yet (another logical drive may
be currently rebuilding). The logical drive will also return to this state if the rebuild had
been aborted due to unrecoverable read errors from another disk.
RECOVERING One or more physical disks in this logical drive are being rebuilt.
WRONG PHYSICAL DISK WAS REPLACED
While the logical drive was in a degraded state, the system was powered off and a disk
other than the failed disk was replaced. Shut off the system and replace the correct
(failed) disk.
PHYSICAL DISK(S) NOT PROPERLY CONNECTED
While the system was off, one or more disks were removed. Note: the other logical drives
are held in a temporary "failed" state when this occurs.
EXPANDING The data in the logical drive is being reorganized because:
1) Physical disks have been added to the array (capacity expansion).
2) The stripe size is being changed (stripe-size migration).
3) The RAID level is being changed (RAID-level migration).
NOT YET AVAILABLE
A capacity expansion operation is in progress (or is queued up) that will make room on
the disks for this new logical drive. Until room has been made on the physical disks, this
newly configured logical drive cannot be read or written.
QUEUED FOR EXPANSION
The logical drive is waiting to undergo data reorganization (see EXPANDING above).
Possible causes for the delay are a rebuild or expansion operation may already be in pro-
gress.
Physical Disk State Definitions
OK The physical disk is configured in one or more logical drives and is operational.
SPARE The physical disk is configured as a spare disk.
UNASSIGNED The physical disk has not been configured in any logical drives.
FAILED The configured physical disk has failed.
RETURN VALUE
sautil returns the following values:
0 Successful completion.
1 Command line syntax error.
2 Incompatible CISS driver API.
3 Failure opening a file.
4 Other error.
EXAMPLES
Display RAID subsystem information for the controller
/dev/ciss5:
sautil /dev/ciss5
Update the firmware on the controller /dev/ciss5 using the firmware image file
/opt/raidsa/bin/MAXWELL332.BIN:
4 Hewlett-Packard Company 4 HP-UX 11i Version 3: March 2011