parconfig.1m (2010 09)

p
parconfig(1M) parconfig(1M)
option) in the recommended configuration of the partition.
parconfig -O HPUX_11iV3 -p 0 -c 1:floating:y: -n numcells:5
By default, the core cell of partition 0 will be retained back in the recommended configuration of the par-
tition. Assuming cell located in cabinet 0, slot 0 is core cell of partition 0 and cells located in cabinet 0 at
slot 2,3,4,5 are free, the output of the
parconfig command will be:
parmodify -p 0 -m 0:base:::87.5% -m 1:floating:y:float:100%
-a 2:base:::87.5% -a 3:base:::87.5% -a 4:base:::87.5%
-a 5:floating:::100% -d 6
Get a recommended configuration for existing local nPartition. An existing partition 1 has to be modified.
Cells in the recommended configuration of the partition should have at least 16 CPUs and 64GB memory.
Cell type should be floating for both the cells.
parconfig -O HPUX_11iV3 -p 1 -n mincpus:16 -n minmem:64
-X LORA -Z low_cost
By default, the core cell of partition 1 will be retained back in the recommended configuration of the par-
tition. Cell located in cabinet 0, slot 0 is the core cell of partition 1 and has 8 CPUs, 32GB memory.
Another cell located in cabinet 0, slot 1 has 8 CPUs and 32GB memory. The output of the
parconfig
command will be:
parmodify -p 1 -m 0:floating:::100% -a 1:floating:::100%
DEPENDENCIES
This command uses the Web-Based Enterprise Management (WBEM) product and some of its
configuration settings. If you encounter connection errors when using the
-u option, check that the fol-
lowing two conditions are satisfied:
Use the
cimconfig command (see cimconfig(1M) in the WBEM product documentation) to verify
(and correct if necessary) the setting of the following two variables:
enableRemotePrivilegedUserAccess=true
enableHttpsConnection=true
The target partitions digital certificate has been appended to the local partitions Shared Authentica-
tion Store. For the nPartition commands, the Shared Authentication Store is stored in the file:
/etc/opt/hp/sslshare/known_hosts.pem
. This file is used by all the clients, which use SSL
based certificates. If these clients trust a target partition, then the nPartition commands will also
trust the target partition.
Refer to the WBEM documents specified in the SEE ALSO section below for further information.
AUTHOR
parconfig was developed by the Hewlett-Packard Company.
SEE ALSO
fruled(1), parstatus(1), cplxmodify(1M), frupower(1M), parcreate(1M), parmgr(1M), parmodify(1M),
parolrad(1M), parremove(1M), parunlock(1M), partition(5).
nPartition Administrator’s Guide on http://www.hp.com/go/hpux-core-docs
,
HP WBEM Services for HP-UX System Administrators Guide on
http://www.hp.com/go/hpux-
core-docs,
HP WBEM Services for HP-UX 11i v2.0 on Integrity Servers Version A.01.05 Release Notes on
http://www.hp.com/go/hpux-core-docs
.
HP-UX 11i Version 3: September 2010 5 Hewlett-Packard Company 5