instl_adm.4 (2012 03)
i
instl_adm(4) instl_adm(4)
and other utilities used to verify and update hardware functionality. This value defaults to a size
expected by the diagnostics software. A zero value indicates that no HP Service Partition should be
created. This variable is adjusted to the minimum HP Service Partition size if set to a non-zero
value less minimum. This variable is supported starting with HP-UX B.11.23 and only supported
on Itanium-based systems.
_hp_force_autoboot
String variable used to modify the behavior of Ignite-UX behavior with respect to stable store’s auto-
boot flag. The Ignite-UX configuration process has two parts separated by a reboot. By default
_hp_force_autoboot
is set to YES, guaranteeing that the Ignite-UX autoboot flag is set during
the installation process and then reset to its previous state (if necessary) at the end of the installa-
tion. If
_hp_force_autoboot=NO
, Ignite-UX will not touch the autoboot flag in stable storage.
Note that this may mean that you will have to perform a manual boot from the primary path
between the two parts of the Ignite-UX installation.
_hp_force_setboot_path
Boolean-string variable for installs of HPUX B.11.31 and later, when set to "true", the lunpath
hardware path (for example 0/1/1/0.0x1.0x0) that is selected as the root disk will be supplied to the
setboot command. When set to "false", the persistent device special file (for example
/dev/rdisk/disk3) will be supplied to the
setboot command. For more details on setboot behavior
see setboot (1M). The default is "false" if not explicitly set.
_hp_loadfile_use_nfs
When set to "true", causes Ignite-UX to use NFS instead of TFTP to transfer files from the Ignite-UX
server. The default is "false" if not explicitly set.
_hp_ht_enable
Boolean-string variable that indicates whether to enable HyperThreading on HyperThread-capable
systems, as reported by the is_ht_capable
variable. Available on HP-UX B.11.31 or later.
_hp_ignore_prior_config
Boolean-string variable that can be used to prevent the use of the
config file in the client’s
/var/opt/ignite/clients/<client> directory. When set to "true" any pre-existing
config file will be
renamed to
config.ignore and then be ignored. The user interface will not give any choice to
use the prior config file when this variable is set to "true". The default is for the client’s
config
file to be used. To take effect, this variable must be set in the
*INSTALLFS file using
instl_adm.
_hp_ignore_sw_impact
Integer variable that may be set to 1 to disable all effects the impacts statements declared in the
software selections on the volume size calculations. This may be helpful to ensure Ignite-UX does
not automatically modify the file system volume sizes.
_hp_keyboard
String variable the UI sets to the keyboard language/mapping desired. The
kbdlang keyword
used for this in past releases is equivalent to this variable. Setting this variable in the
*INSTALLFS file using instl_adm prevents the system from prompting for a keyboard type dur-
ing the installation. This information is stored in /etc/kbdlang on the final client.
_hp_lanadmin_args
If your network requires the default attributes of a lan interface be changed via the lanadmin
command to operate correctly, you can specify the arguments to the lanadmin command via this
variable. This setting must be performed in an installation file system using the instl_adm com-
mand. For more information on the options available for lanadmin, refer to the lanadmin (1M)
manual page.
Any changes made with this variable are in effect during the installation only; they are not applied
to the system permanently.
To set the speed and duplex values for a 100BT interface to 100 full duplex:
( lan[].driver ˜ "btlan" ) {
_hp_lanadmin_args="-X 100FD"
}
In the example configuration above, when Ignite-UX finds lan[].driver, it uses the variable
_hp_default_cur_lan_dev as the index.
6 Hewlett-Packard Company − 6 − HP-UX 11i Version 3: March 2012