drd-unrehost.1m

d
drd-unrehost(1M) drd-unrehost(1M)
NAME
drd unrehost - remove the system information file, EFI/HPUX/SYSINFO.TXT, from the EFI partition of a
disk previously specified as the target of a "drd rehost" command, and optionally preserve a copy of it in a
file on the booted system.
SYNOPSIS
drd unrehost
[-?][-p] -f system_information_file [
-q][-t target_device_file][
-v]
[
-x option=
value][-x -?][-X option_file]
DESCRIPTION
The
drd unrehost command removes EFI/HPUX/SYSINFO.TXT
, and optionally preserves a copy of
it in a file on the booted system.
A system administrator can execute the
drd unrehost
command after having previously issued the
drd rehost command, specifying the same target, if the disk should not be rehosted.
The format of the
sysinfo file is defined in sysinfo (4). To determine the most recent patch that supplies
sysinfo (4), please consult the DRD web site,
http://www.hp.com/go/DRD
.
Options
drd rehost
recognizes the following options:
-? Displays the usage message.
-p Sets preview mode.
-f Specifies the file to which the EFI/HPUX/SYSINFO.TXT
is to be copied. If not specified, the file
is not copied.
-q Decreases the verbosity level by one each time it is specified. For example,
-qq will reduce the
verbosity from the default value of 4 to 2. If both
-x verbosity=5 and -qqq are included on
the command line, the effective verbosity is 2. The minimum verbosity level is 0. (See also the
-x verbosity option).
-v Increases the verbosity level by one each time it is specified. For example,
-v will increase the
effective verbosity from the default value of 4 to 5. If both
-x verbosity=1 and
-vv are
included on the command line, the effective verbosity is 3. The maximum verbosity level is 5.
(See also the
-x verbosity option).
-x -? Displays the list of possible -x (extended) options.
-x option=value
Sets the extended option to a value. See Extended -x Options definitions below.
-X option_file
Gets the extended options from a file.
-t device_special_file
Specifies the block device special file of a single writable physical disk from whose EFI partition
the file EFI/HPUX/SYSINFO.TXT is to be removed. If no target is specified, the inactive sys-
tem image is used as a target.
Extended -x Options
drd rehost recognizes the following -x (extended) options:
-x logfile=/var/opt/drd/drd.log
Usage: Basic
This is the path to the log file for this command. Each time DRD is run, this file will grow larger.
This can be changed, for example, to a month-specific location for easier archiving, off-host backup,
and rotation.
-x log_verbosity=4
Usage: Basic
Specifies the level of message verbosity in the log file (See also -x verbosity). Legal values are:
0 Only ERROR messages and the starting/ending BANNER messages.
1 Adds WARNING messages.
2 Adds NOTE messages.
3 Adds INFO messages (informational messages preceded by the * character).
HP-UX 11i Version 3: September 2010 1 Hewlett-Packard Company 1

Summary of content (2 pages)