Command Reference Guide
Administration Commands
query_dspu_template
2.130 query_dspu_template
The query_dspu_template command returns information about defined downstream PU templates used for
PU concentration over implicit links.
2.130.1 Supplied Parameters
Parameter name Type Length Default
[query_dspu_template]
num_entries decimal 1
list_options constant LIST_INCLUSIVE
template_name character 8 (null string)
Supplied parameters are:
num_entries
Maximum number of entries for which data should be returned. You can specify 1 to return data for a specific
template, a number greater than 1 to return data for multiple templates, or 0 (zero) to return data for all
templates.
list_options
The position in the list of entries from which SNAplus2 begins to return data.
Possible values are:
FIRST_IN_LIST
Start at the first entry in the list
LIST_INCLUSIVE
Start at the entry specified by the template_name parameter
LIST_FROM_NEXT
Start at the entry immediately following the entry specified by the template_name parameter
template_name
Name of the DSPU template for which information is required, or the name to be used as an index into
the list. Specify 1–8 locally displayable characters. This parameter is ignored if list_options is set to
FIRST_IN_LIST.
2.130.2 Returned Parameters
Parameter name Type Length
template_name character 8
description character
max_instance decimal
active_instance decimal
num_of_dslu_templates decimal
{dslu_template}
min_nau decimal
max_nau decimal
allow_timeout constant
delayed_logon constant
host_lu character 8
381