HP-UX Directory Server 8.1 administrator guide

Table 8-7 Replication errors (continued)
RemedyImpactReasonError/symptom
Synchronize the system
clocks on the Directory
Server host machines. If
applicable, run the network
time protocol (ntp) daemon
on those hosts.
The system clock is used
to generate a part of the
CSN. In order to reflect the
change sequence among
multiple suppliers,
suppliers would
forward-adjust their local
clocks based on the remote
clocks of the other
suppliers. Because the
adjustment is limited to a
certain amount, any
difference that exceeds the
permitted limit will cause
the replication session to
be aborted.
The system clocks on the
host machines are extremely
out of sync.
Too much time skew
Watch if the consumer can
receive any new change from
any of its suppliers, or start
the replication monitor, and
see if all the suppliers of this
consumer warn that the
replica is busy. If the replica
appears to be locked forever
and no supplier can get in,
restart the consumer.
If the consumer recovers
without being restarted,
there is a chance that the
replica on the consumer
will be locked forever if it
did not receive the release
lock message from the
supplier.
The consumer is not
responding.
agmt=%s(%s:%d):
Warning: Unable to send
endReplication extended
operation (%s)
8.19 Troubleshooting replication-related problems 391