Reference Guide
174 Chapter 8
Diagnostic Messages
Error Messages
1101 MESSAGE Standard input must be a pipe
or FIFO, not a TTY or device
file.
CAUSE The assembler was invoked without
any input files on the command-line.
For this situation the assembler will
then attempt to use the standard
input of a UNIX pipe command. The
object file will be written to standard
output for this case. However, before
assembling the standard input, the
assembler will attempt to discover if
the standard input file is associated
with a TTY or terminal. If the
assembler determines that standard
input is associated with a TTY or
terminal then it prints this error
message and exits.
ACTION Supply a filename when invoking the
assembler, or use a UNIX pipe to
provide an input file for the
assembler.
1102 MESSAGE Displacement of %s must be
multiple of four
CAUSE The displacement in this instruction
must be a multiple of four.
ACTION Use a displacement that is a multiple
of four.
1103 MESSAGE Displacement of %s must be
zero with ,O
CAUSE The displacement must be zero when
using the ,O completer.
ACTION Use a displacement of zero.
1104 MESSAGE Displacement can't be zero
with ,MA
CAUSE The displacement cannot be zero
when using the ,MA completer.