HP CIFS Server 3.0b Administrator's Guide version A.02.01.01

Configuring HA HP CIFS
Overview of HA HP CIFS Server
Chapter 11 237
6. The following initialization will cause package failover to occur if
there is a node or network failure, even if the HP CIFS Server
monitor script is not being used.
PKG_SWITCHING_ENABLED YES
NET_SWITCHING_ENABLED YES
7. If NODE_FAIL_FAST_ENABLE is set to NO, the node is not brought down
when the package goes down.
NODE_FAIL_FAST_ENABLED NO
Edit the samba.cntl Control Script
To configure the samba.cntl Control Script file, you must complete the
following tasks:
1. Set the NETBIOS_NAME variable to your NetBIOS name.
NETBIOS_NAME=ha_server1
...for sambapkg1 and
NETBIOS_NAME=ha_server2
...for sambapkg2, etc.
2. Create a volume group for the HP CIFS Server directories:
VG[0]=/dev/vgsambapkg1
...for sambapkg1, and
VG[0]=/dev/vgsambapkg2
...for sambapkg2, etc.
3. Create a separate LV[n] and FS[n] variable for each volume group
and file system that will be mounted on the server, for example:
LV[0]=/dev/vgsambapkg1/lvol1;FS[0]=/opt/share1
LV[1]=/dev/vgsambapkg1/lvol2;FS[1]=/home/share2
Add more LVs if required for sambapkg.
LV[0]=/dev/vgsambapkg2/lvol1;FS[0]=/opt/share1
LV[1]=/dev/vgsambapkg2/lvol2;FS[1]=/home/share2
Add more LVs if required for sambapkg2.
4. Specify the relocatable IP address and the address of the subnet to
which the IP address belongs: