HP-UX WBEM Services Release Notes (B8465-90045, March 2011)
Table 5 Defects fixed in HP WBEM Services Version A.02.09.xx (continued)
ResolutionDescriptionIdentifier
This defect is fixed in the current release.
With this fix, cimserver now removes any
/var/opt/wbem/localauth file
created for connections that are
terminated before authentication is
completed.
When clients running on the localhost,
connecting via the connectlocal( )
method, terminate the connection before
authentication is completed, the authentication
token is not removed from /var/opt/wbem/
localauth file.
QXCR1001066307
This defect is fixed in the current release.When upgrading from HP-UX 11i v2 OS to
HP-UX 11i v3 OS, the WBEMServices filesets
and all filesets dependent on WBEM are not
configured correctly in an LDAP environment.
During the configure phase of WBEMServices,
error messages are seen.
QXCR1001071978
With the current fix, cimserverd daemon
monitors the status of both cimserver and
cimservermain processes and restarts
cimserver if either one of the process is
not active.
The cimserverd daemon checks if the
cimservermain process is running and restarts
cimserver if cimservermain is not active.
QXCR1001060784
This defect is fixed in the current release.
With this fix, the wbeminfo.sh script
is enhanced to display all the registered
providers and the corresponding classes
on a system.
During previous release, the wbeminfo.sh
script does not display all the registered
providers and the corresponding classes on a
system.
QXCR1001064867
Defects fixed in A.02.09.04
This defect has been fixed such that the
IndicationTime property displays the
accurate local time.
The IndicationTime property of the
HP_AlertIndication class does not display
the Coordinated Universal Time (UTC). The
event time in the indications that are received
do not match with the local time of the system.
QXCR1001017205
Defects fixed in A.02.09.02
This defect has been fixed such that this
memory leak does not occur.
A memory leak occurs in the cimprovagt
process when the loaded provider reaches the
value specified for the max_thread_proc
parameter. Also, all subsequent
pthread_create() calls fail.
QXCR1000962884
The HP WBEM Services Release Notes
document has been updated with the
correct versions of the SCSI and SAS
provider.
The September 2009 version of the HP WBEM
Services Release Notes specified incorrect
versions of the SCSI provider and SAS
provider.
QXCR1000984017
Defects fixed in A.02.09
18 HP WBEM Services Version A.02.09.06 Release Notes