HP-UX WBEM SCSI Provider Release Notes (September 2013)

Table 5 Defect Fix in HP-UX 11i v2 OS
DescriptionDefect ID
Defect fix in B.11.23.1004 release
In the previous version, SCSI Consolidated Status provider returns no value for
HPUX_SCSIPortControllerCollection class if SCSI cards are not installed
QXCR1000905943
on the machine. Due to this defect, the System Management Homepage displays
incorrect consolidated status of the cards.
In the current version this defect is fixed, and the class returns an instance of
HPUX_SCSIPortControllerCollection class with
GroupOperationalStatus as OK. As a result, the System Management
Homepage displays correct consolidated status even if SCSI cards are not installed
on the system.
Table 6 Defect fix in HP-UX 11i v3 OS
DescriptionDefect ID
Defect fix in B.11.31.0903 release
In the previous version, the deviceID property of the SCSI HBA was not displayed
on the SMH web page of the subsystem. In the current release, the deviceID property
of the SCSI HBA is displayed on the SMH web page.
QXCR1000905943
Defect fix in B.11.31.1009 release
In the previous release, on HP-UX system, enumerate instance of
HPUX_SCSIPortControllerCollection class returns incorrect data when
SCSI port controllers are not present.
QXCR1001029293
In the current release, this defect is fixed.
In the previous release, SCSI Indication provider does not display multiple IP
addresses available on a system.
QXCR1000996827 / QXCR1001023213
In the current release, SCSI Indication provider displays multiple IP addresses
available on a system.
In the previous release, SCSI Consolidated Status provider displays erroneous data
on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, SCSI Consolidated Status provider is disabled on HP
Virtual Machine guest systems.
Known problems, workaround, and limitations
There are no known problems and workaround in the current release.
Following are the limitations of the SCSI provider:
It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related documentation
Table 7 lists the available documentation for the WBEM providers:
Table 7 WBEM provider related documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
8 SCSI provider release notes for September 2013 release