HP-UX WBEM SAS Provider Release Notes, December 2010

Adaptor List for the Events Supported by the Provider
For more information about the adaptor events supported by the provider on HP-UX 11i v2 and
HP-UX 11i v3 OS, see http://docs.hp.com/en/diag/ems/dm_sas_adapter.htm.
Defects Fixed in This Version
This section describes the WBEM SAS Provider defects fixed in the HP-UX 11i v2 and HP-UX 11i
v3 operating systems.
Table 6 Defects Fixed in the HP-UX 11i v2 OS
DescriptionDefect ID
Defect Fix in B.11.23.1012 Release
In the previous version, property details of SAS HBA is not displayed on HP SMH
web page under the Storage subsystem.
In the current release, this defect is fixed. Property details of SAS HBA is displayed
on HP SMH web page under the Storage subsystem.
QXCR1001039271
Table 7 Defects Fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defect Fix in B.11.31.0909 Release
In the previous version, the deviceID property of the SAS HBA was not displayed
on the HP SMH web page of the subsystem.
In the current version, the deviceID property of the SAS HBA is displayed on the HP
SMH web page of the subsystem.
QXCR1000904989
Defects Fixed in B.11.31.1004 Release
In the previous release, events generated by all I/O Indication providers were
logged in SAS provider database SASPROVDB, available at the location:/opt/
psb/db/pgsql/bin/psql
In the current release, events generated only by SAS Indication provider gets logged
in the SASPROVDB database, available at the location: /opt/psb/db/pgsql/
bin/psql.
QXCR1001013221
In the previous release, to generate SAS Indications, OnlineDiag monitor
dm_sas_adapter needs to be restarted several times.
In the current release, this defect is fixed.
QXCR1001009142
In the previous release, following fields were not populated with appropriate values
from the indications generated by HPUXSASIndicationProviderModule and
HPUXSASNativeIndicationProviderModule:
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXSASIndicationProviderModule and
HPUXSASNativeIndicationProviderModule.
QXCR1001012655 / QXCR1000996830
In the previous release, after OE install, reboot, or upgrade, the SAS Indication
module times-out while registering with EMS.
In the current release, this defect is fixed by increasing the time-out value of EMS
registration.
QXCR1001001392
Adaptor List for the Events Supported by the Provider 7