HP-UX WBEM SAS Provider release notes (5900-2476, September 2012 web release)
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the current release, SAS indication and Consolidated Status provider is disabled
on HP Virtual Machine guest systems.
In the previous release, SAS indication provider does not display multiple IP
addresses of a system.
QXCR1000996827 / QXCR1001023213
In the current release, SAS indication provider displays multiple IP addresses of a
system.
Defects fixed in B.11.31.1103 release
In the previous release, on BL870c i2 platform, the SAS disk test command:QXCR1001058688
#/opt/sas/provider/bin/SAS_Provider_Test -d fails to generate events
for all SAS disks available on the system if the first instance of the disk is not
supported by the HPUXSASNativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk test is
enhanced to send events for all the monitored paths even if the first instance of the
disk is not supported by the HPUXSASNativeIndicationProviderModule.
In the previous release, the HPUXSASIndicationProviderModule displays
incorrect severity value after registering with EMS sub-system on HP-UX 11i v3 OS.
QXCR1001048021
The moncheck utility output, used to view the status of OnlineDiag monitors,
displays incorrect severity value.
This defect is fixed in the current release. The
HPUXSASIndicationProviderModule displays appropriate severity value after
registering with EMS sub-system on HP-UX 11i v3 OS.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available in
SAS Instance provider and SAS Consolidated Status provider fails for a user with
non-root privileges.
QXCR1001068706
This defect is fixed in the current release. Enumeration of classes available in SAS
Instance provider and SAS Consolidated Status provider is successful even for a
normal user.
In the previous release on the BL870c i2 platform, when the cimserver /
HPUXSASNativeIndicationProviderModule is restarted, the Indication
QXCR1001078598
Identifier index is reset. If the evweb current database already has events with the
same event number or Indication Identifier index, such duplicate events are not
logged in the evweb database. When events with same event IDs are reported
frequently, the events will be logged in the /var/opt/sfm/log/event.log file
and the syslog file.
In the current release on the BL870c i2 platform, when the cimserver /
NativeFCIndicationProvider is restarted, the Indication Identifier is
concatenated with a timestamp along with the event number and Index. With this
modification, the Indication Identifier can never be duplicated and all the event IDs
generated by the HPUXSASNativeIndicationProviderModule are unique,
which gets logged in the evweb database.
Defects fixed in B.11.31.1109 release
In the previous release, core file generated by cimprovagt, program terminated
with signal 11, resulting in segmentation fault.
QXCR1001051369
This defect is fixed in the current release.
In the previous release, the HPUXSASIndicationProviderModule data had
junk values at the end in evweb o/p under "Error Details/Component Data".
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS API
which fills the "Error Details/Component Data".
Defects fixed in B.11.31.1203 release
8 HP-UX WBEM SAS provider release notes