HP-UX WBEM SAS Provider release notes (5900-2476, September 2012 web release)

Table 7 Defects fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defect fix in B.11.31.0909 release
In the previous version, the deviceID property of the SAS HBA was not displayed
on the HP SMH web page of the subsystem.
QXCR1000904989
In the current version, the deviceID property of the SAS HBA is displayed on the HP
SMH web page of the subsystem.
Defects fixed in B.11.31.1004 release
In the previous release, events generated by all I/O indication providers were
logged in SAS provider database SASPROVDB, available at: /var/opt/psb/db/
pgsql.
QXCR1001013221
In the current release, events generated only by SAS indication provider gets logged
in the SASPROVDB database, available at: /var/opt/psb/db/pgsql.
In the previous release, to generate SAS Indications, OnlineDiag monitor
dm_sas_adapter needs to be restarted several times.
QXCR1001009142
In the current release, this defect is fixed.
In the previous release, the following fields were not populated with appropriate
values from the indications generated by HPUXSASIndicationProviderModule
and HPUXSASNativeIndicationProviderModule:
QXCR1001012655 / QXCR1000996830
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXSASIndicationProviderModule and
HPUXSASNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the SAS indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS
registration.
In the previous release, system log configuration file for SAS provider available at:
/opt/sas/provider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for SAS provider available at: /opt/
sas/provider/conf is termed as SASLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData
indication properties of HPUXSASIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
Defects fixed in B.11.31.1009 release
In the previous release, the HPUXSASIndicationProviderModule dumps core
when ComponentData indication properties are not retrieved successfully.
QXCR1001021614
In the current release, this defect is fixed and
HPUXSASIndicationProviderModule does not dump core.
In the previous release, SAS provider event details were not formatted correctly on
legacy systems. This defect is fixed in the current release.
QXCR1000993005
In the previous release, SAS indication and Consolidated Status provider displays
erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
Defects fixed in the version 7