HP-UX WBEM SAS Provider Release Notes (5900-1496, March 2011)

Table 7 Defects Fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the previous release, the HPUXSASIndicationProviderModule displays
incorrect severity value after registering with EMS sub-system on HP-UX 11i v3 OS.
The moncheck utility output, used to view the status of OnlineDiag monitors,
displays incorrect severity value.
This defect is fixed in the current release. The
HPUXSASIndicationProviderModule displays appropriate severity value after
registering with EMS sub-system on HP-UX 11i v3 OS.
QXCR1001048021
In the previous release on HP-UX 11i v3 OS, enumeration of classes available in
SAS Instance provider and SAS Consolidated Status provider fails for a user with
non-root privileges.
This defect is fixed in the current release. Enumeration of classes available in SAS
Instance provider and SAS Consolidated Status provider is successful even for a
normal user.
QXCR1001068706
In the previous release on the BL870c i2 platform, when the cimserver /
HPUXSASNativeIndicationProviderModule is restarted, the Indication
Identifier index is reset. If the evweb current database already has events with the
same event number or Indication Identifier index, such duplicate events are not
logged in the evweb database. When events with same event IDs are reported
frequently, the events will be logged in the /var/opt/sfm/log/event.log file
and the syslog file.
In the current release on the BL870c i2 platform, when the cimserver /
NativeFCIndicationProvider is restarted, the Indication Identifier is
concatenated with a timestamp along with the event number and Index. With this
modification, the Indication Identifier can never be duplicated and all the event IDs
generated by the HPUXSASNativeIndicationProviderModule are unique,
which gets logged in the evweb database.
QXCR1001078598
Known Problems, Workarounds, Limitations
There are no known problems and workarounds in the current release.
Following is the limitation of the SAS provider:
SAS is a read-only provider and hence does not allow users to modify, create, or delete
instances.
Related Documentation
Table 8 lists the available documentation for the WBEM providers:
Table 8 WBEM Provider Related Documents
LocationDescription
http://www.dmtf.org/education/cimtutorial.phpCIM Tutorial
http://software.hp.com
and
http://www.hp.com
Information about HP WBEM Services
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the Indication Schema
Datasheets of all the providers are installed along with the product at the following
location on the system:/opt/<provider-name>/doc
The datasheets are also available at the following location:
www.hp.com/go/hpux-networking-docs and select HP-UX 11i WBEM Software
collection.
Provider Datasheets
8 HP-UX WBEM SAS Provider Release Notes