HP-UX WBEM RAIDSA Provider Release Notes

Defects Fixed in This Version
The following defects are fixed in the RAIDSA provider for March 2009 release. To view entire
details of each defect fix, refer to the HP IT Resource Center at: http:// forums1.itrc.hp.com/service/
forums/home.do
Table 1-3 lists the defect fixes for HP-UX 11iv2 and HP-UX 11iv3 OS
Table 1-3 March 2009 Defect Fixes for HP-UX 11i v2 and HP-UX 11i v3 OS
DescriptionDefect ID
RAIDSA-CS provider returns empty response to
HPUX_RAIDSAPortControllerCollection class if there are no smart
array HBAs installed on the machine. But, the provider should return an
instance of HPUX_RAIDSAPortControllerCollection class with
GroupOperationalStatus value as OK.
This is fixed to return an instance of
HPUX_RAIDSAPortControllerCollection with
GroupOperationalStatus value as OK.
QXCR1000834118
10 HP-UX WBEM RAIDSA Provider Release Notes