HP-UX WBEM RAIDSA Provider Release Notes HP-UX 11i v2 and HP-UX 11i v3 (5900-1993, September 2011 web release)

Table 7 Defects Fixed in the HP-UX 11i v3 OS (continued)
Table 8 (continued)
Earlier Severity LevelCurrent Severity Level
Subsystem
GroupOperationalStatus
Unknown(0) and
No Contact(12).
Stopping(9)
In Service(11)
Dormant(15)
Power Mode(18)
Has higher severity
level than the states
Has less severity level than
the states OK(2) and
Completed(17).
Unknown(0)
No Contact(12)
OK(2) and
Completed(17).
Has the lowest
severity level.
Has the highest severity
level.
OK(2)
Completed(17)
In the previous release, cimprovagt program generated a core during unload
of the Provider. The program was terminated with signal 11, segmentation
fault.
QXCR1001051369
In the current release, this problem is fixed.
Defects Fixed in the B.11.31.1109 Release
In the previous release, the RAIDSAProvider test binary was available in
/opt/raidsaprovider/lib directory.
QXCR1001087415
In the current release, the RAIDSAProvider test binary has been moved to
/opt/raidsaprovider/bin directory.
In the previous release, the HPUXRAIDSAIndicationProviderModule
data had junk values at the end in evweb o/p under "Error Details/Component
Data."
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS
API which fills the "Error Details/Component Data."
Known Problems, Workarounds, Limitations
The following known problems are for the current release:
When RAIDSA Provider B.11.31.1106 or later is installed on legacy Integrity systems,
dm_raid_adapter is never launched regardless of the diag mode.
HPUXRAIDSAIndicationProviderModule always monitors natively the hardware and generates
WBEM events. The reverse wrapper, RAID_WbemWrapperMonitor, may be launched
depending on the connected hardware. These reverse wrappers convert the WBEM event to
the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource path:
/adapters/events/raid_wbem_wrapper
On the other hand, as the process for disk_em and msamon_sas are never launched, the
corresponding EMS resource path are not monitored:
/adapters/events/raid_adapter
Problem: No e-mail alerts for the subscription.
Description: Users will not receive e-mail alerts for existing and new e-mail subscriptions due
to database authorization issue in September 2011 release.
10 HP-UX WBEM RAIDSA Provider release notes