HP-UX WBEM RAIDSA Provider Release Notes HP-UX 11i v2, HP-UX 11i v3 HP Part Number: 5900-2478 Published: September 2012 web release
Legal Notices © Copyright 2003, 2012 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents 1 HP-UX WBEM RAIDSA provider release notes................................................4 Announcement.........................................................................................................................4 HP-UX WBEM RAIDSA provider..................................................................................................4 What's new in this release.........................................................................................................
1 HP-UX WBEM RAIDSA provider release notes This document discusses the most recent product information on HP-UX WBEM RAIDSA provider, which is supported on HP-UX 11i v2 and HP-UX 11i v3 operating systems. Table 1 (page 4) lists the product versions for which the document is applicable. Table 1 Documentation Support for RAIDSA provider Operating system Version HP-UX 11i v3 B.11.31.1209.10.
What's new in this release • For every PCI OL* suspend operation on a RAIDcard owned by ciss driver, theHPUXRAIDSANativeIndicationProvider generates only one event #4 per card instead of generating two events 3,4 for each port on the card. • For every PCI OL* resume operation on a RAIDcard owned by ciss driver, theHPUXRAIDSANativeIndicationProvider generates only one event #7 per card instead of generating two events 6,7 for each port on the card.
Table 3 RAIDSA provider supported platforms (continued) Provider name Product name Supported platforms HP Legacy Integrity servers • cx2600 • cx2620 • rx1600 • rx1620 • rx2600 • rx2620 • rx2660 • rx3600 • rx4640 • rx5670 • rx6600 • rx7620 • rx7640 • rx8620 • rx8640 • SD16A, SD32A, SD64A • SD16B, SD32B, SD64B • BL60p HP Server Blade • BL860c HP Server Blade • BL870c HP Server Blade • HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blades • rx2800 i2 • HP Integrity Superdome 2 NOTE: Wrapper indication
Disk space requirement Table 5 lists the disk space requirement for the RAIDSA provider.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) In the current release, events generated only by RAIDSA indication provider gets logged in the RAIDSAPROVDB database, available at the location: /var/opt/psb/db/pgsql.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) QXCR1001048021 In the previous release, the HPUXRAIDSAIndicationProviderModule displays incorrect severity value after registering with EMS sub-system on HP-UX 11i v3 OS. The moncheck utility output, used to view the status of OnlineDiag monitors, displays incorrect severity value. This defect is fixed in the current release.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) Table 8 (continued) Subsystem GroupOperationalStatus Current Severity Level Earlier Severity Level Unknown(0) and No Contact(12). • Stopping(9) • In Service(11) • Dormant(15) • Power Mode(18) • Unknown(0) • No Contact(12) • OK(2) • Completed(17) QXCR1001051369 Has less severity level than the states OK(2) and Completed(17). Has higher severity level than the states OK(2) and Completed(17). Has the highest severity level.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) This issue is fixed in this release. Defects fixed in version B.11.31.1209.08.01 QXCR1001206587 Bay and enclosure values are incorrectly displayed for RAIDSAProvider. Bay value is displayed as enclosure value and vice versa. This issue is fixed in this release. The Bay and enclosure values are correctly displayed. QXCR1001198841 During multiple system reboot, past provider events get reported for RAIDSA provider.
Workaround: There is no workaround for this problem. • Problem: The events are lost when diagnostic products are upgraded on a DRD cloned disk. Description: Prior to September 2012 release version of diagnostics product, the postgres 7.4.2 version was supported. However version 8.4.8 is shipped from September 2012 release. Due to the missing data compatibility between PostgreSQL version 7.4.2 (prior to September 2012) and 8.4.
2 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.