HP-UX WBEM RAIDSA Provider Release Notes HP-UX 11i v2, HP-UX 11i v3 HP Part Number: 5900-2322 Published: September 2012
Legal Notices © Copyright 2003, 2012 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Contents 1 HP-UX WBEM RAIDSA provider release notes................................................4 Announcement.........................................................................................................................4 HP-UX WBEM RAIDSA provider..................................................................................................4 What's new in this release.........................................................................................................
1 HP-UX WBEM RAIDSA provider release notes This document discusses the most recent product information on HP-UX WBEM RAIDSA provider, which is supported on HP-UX 11i v2 and HP-UX 11i v3 operating systems. Table 1 (page 4) lists the product versions for which the document is applicable. Table 1 Documentation Support for RAIDSA provider Operating system Version HP-UX 11i v3 B.11.31.1209.08.
Installing HP-UX WBEM RAIDSA provider The latest WBEM RAIDSA provider depot is available for download on the OE media. It is also available on the Web for download at: http://h18013.www1.hp.com/products/servers/ management/hpsim/dl_hpux.html#managed For more information on installing the providers, see the Website at: http://h20392.www2.hp.com/ portal/swdepot/displayProductInfo.
Table 3 RAIDSA provider supported platforms (continued) Provider name Product name Supported platforms • rx8640 • SD16A, SD32A, SD64A • SD16B, SD32B, SD64B • BL60p HP Server Blade • BL860c HP Server Blade • BL870c HP Server Blade • HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blades • rx2800 i2 • HP Integrity Superdome 2 NOTE: Wrapper indication provider is supported on HP 9000 servers. Native indication provider is supported on Integrity servers.
PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe PCIe SAS SAS SAS SAS SAS SAS SAS SAS SAS SAS SmartArray SmartArray SmartArray SmartArray SmartArray SmartArray SmartArray SmartArray SmartArray SmartArray P400 RAID Controller P400i RAID Controller P800 RAID Controller P700 RAID Controller P212 RAID Controller P410 RAID Controller P410i RAID Controller P411 RAID Controller P812 RAID Controller P711m RAID Controller For more information about the events that are supported by the provider, see http:// bizsuppor
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) QXCR1001001392 In the previous release, after OE install, reboot, or upgrade, the RAIDSA indication module times-out while registering with EMS. In the current release, this defect is fixed by increasing the time-out value of EMS registration. QXCR1000947233 In the previous release, system log configuration file for RAIDSA provider available at: /var/opt/raidsaprovider/conf is termed as PSBLoggerConfig.xml.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) events are not logged in the evweb database. When events with the same IDs are reported frequently, the events will be logged in the /var/opt/sfm/log/ event.log file and the syslog file. In the current release on BL870c i2 platform, when the cimserver / HPUXRAIDSANativeIndicationProviderModule is restarted, the Indication Identifier is concatenated with a timestamp along with the event number and Index.
Table 7 Defects fixed in the HP-UX 11i v3 OS (continued) QXCR1001087415 In the previous release, the RAIDSAProvider test binary was available in /opt/raidsaprovider/lib directory. In the current release, the RAIDSAProvider test binary has been moved to /opt/raidsaprovider/bin directory. QXCR1001053727 In the previous release, the HPUXRAIDSAIndicationProviderModule data had junk values at the end in evweb o/p under "Error Details/Component Data." This defect is fixed in the current release.
HPUXRAIDSAIndicationProviderModule always monitors natively the hardware and generates WBEM events. The reverse wrapper, RAID_WbemWrapperMonitor, may be launched depending on the connected hardware. These reverse wrappers convert the WBEM event to the corresponding EMS event.
2 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.