HP-UX WBEM RAIDSA Provider release notes (5900-2225, March 2012 web release)

Table 7 Defects fixed in the HP-UX 11i v3 OS (continued)
In the previous release, after OE install, reboot, or upgrade, the RAIDSA
indication module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of
EMS registration.
In the previous release, system log configuration file for RAIDSA provider
available at: /var/opt/raidsaprovider/conf is termed as
PSBLoggerConfig.xml.
In the current release, the log configuration file for RAIDSA provider available
at: /var/opt/raidsaprovider/conf is termed as
RAIDSALoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData
indication properties of HPUXRAIDSAIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
Defects fixed in the B.11.31.1009 release
In the previous release, RAIDSA provider event details were not formatted
correctly on legacy systems. This defect is fixed in the current release.
QXCR1000993005
In the previous release, RAIDSA indication and Consolidated Status provider
displays erroneous data on HP Virtual Machine guest systems.
QXCR1001022697
In the current release, RAIDSA indication and Consolidated Status providers
are disabled on HP Virtual Machine guest systems.
In the previous release, RAIDSA indication provider does not display multiple
IP addresses of a system.
QXCR1000996827 /
QXCR1001023213
In the current release, RAIDSA indication provider displays multiple IP addresses
of a system.
Defects fixed in the B.11.31.1103 release
In the previous release, on BL870c i2 platform, the RAIDSA disk test command:QXCR1001058688
#/opt/raidsaprovider/lib/RAID_Provider_Test -d fails to generate
events for all subsequent RAIDSA disks available on the system if the first
instance of the disk is not supported by the
HPUXRAIDSANativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk test
is enhanced to send events for all the monitored paths even if the first instance
of the disk is not supported by the
HPUXRAIDSANativeIndicationProviderModule.
In the previous release, the HPUXRAIDSAIndicationProviderModule
displays incorrect severity value after registering with EMS sub-system on HP-UX
QXCR1001048021
11i v3 OS. The moncheck utility output, used to view the status of OnlineDiag
monitors, displays incorrect severity value.
This defect is fixed in the current release. The
HPUXRAIDSAIndicationProviderModule displays appropriate severity
value after registering with EMS sub-system on HP-UX 11i v3 OS.
In the previous release on HP-UX 11i v3 OS, enumeration of classes available
in RAIDSA Instance provider and RAIDSA Consolidated Status provider fails
for a user with non-root privileges.
QXCR1001068706
This defect is fixed in the current release. Enumeration of classes available in
RAIDSA Instance provider and RAIDSA Consolidated Status provider is successful
even for a normal user.
In the previous release on BL870c i2 platform, when the cimserver /
HPUXRAIDSANativeIndicationProviderModule is restarted, the
QXCR1001078598
Indication Identifier index is reset. If the evweb current database already has
events with the same event number or Indication Identifier index, such duplicate
8 HP-UX WBEM RAIDSA provider release notes