HP-UX WBEM RAIDSA Provider release notes (5900-2225, March 2012 web release)

PCIe SAS SmartArray P400 RAID Controller
PCIe SAS SmartArray P400i RAID Controller
PCIe SAS SmartArray P800 RAID Controller
PCIe SAS SmartArray P700 RAID Controller
PCIe SAS SmartArray P212 RAID Controller
PCIe SAS SmartArray P410 RAID Controller
PCIe SAS SmartArray P410i RAID Controller
PCIe SAS SmartArray P411 RAID Controller
PCIe SAS SmartArray P812 RAID Controller
PCIe SAS SmartArray P711m RAID Controller
For more information about the events that are supported by the provider, see http://
bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c02620794/c02620794.pdf.
Defects fixed in This version
This section describes the WBEM RAIDSA provider defects fixed in the HP-UX 11i v2 and 11i v3
operating systems.
Table 6 Defects fixed in the HP-UX 11i v2 OS
DescriptionDefect ID
Defects fixed in the B.11.23.1012 release
In the previous version, property details of RAIDSA HBA is not displayed on
HP SMH web page under the Storage subsystem.
QXCR1001039271
In the current release, this defect is fixed. Property details of RAIDSA HBA is
displayed on HP SMH web page under the Storage subsystem.
Table 7 Defects fixed in the HP-UX 11i v3 OS
DescriptionDefect ID
Defects fixed in the B.11.31.1003 release
The /tmp/raidsa_log file gets created because the ioctl() call fails and
returns EINVAL error value.
This defect is fixed in the current release, and the log file is created under the
path /var/opt/raidsaprovider/log with the filename as raidsa.log.
QXCR1000989338
Defects fixed in the B.11.31.1004 release
In the previous release, events generated by all I/O indication providers were
logged in RAIDSA provider database RAIDSAPROVDB, available at the location:
QXCR1001013221
/var/opt/psb/db/pgsql
In the current release, events generated only by RAIDSA indication provider
gets logged in the RAIDSAPROVDB database, available at the location:
/var/opt/psb/db/pgsql.
In the previous release, following fields were not populated with appropriate
values from the indications generated by:
QXCR1001012655 /
QXCR1000996830
HPUXRAIDSAIndicationProviderModule and
HPUXRAIDSANativeIndicationProviderModule:
Event Threshold
Event TimeWindow
SystemSerialNumber
SystemFirmwareVersion
SystemGUID
In the current release, these fields are populated from the indications generated
by HPUXRAIDSAIndicationProviderModule and
HPUXRAIDSANativeIndicationProviderModule.