HP-UX WBEM RAIDSA Provider release notes (5900-1785, September 2011)
Table 7 Defects Fixed in the HP-UX 11i v3 OS (continued)
In the previous release, the RAIDSAProvider test binary was available in
/opt/raidsaprovider/lib directory.
QXCR1001087415
In the current release, the RAIDSAProvider test binary has been moved to
/opt/raidsaprovider/bin directory.
In the previous release, the HPUXRAIDSAIndicationProviderModule
data had junk values at the end in evweb o/p under "Error Details/Component
Data."
QXCR1001053727
This defect is fixed in the current release. Void Pointer is passed to the EMS
API which fills the "Error Details/Component Data."
Known Problems, Workarounds, Limitations
The following known problems are for the current release:
• When RAIDSA Provider B.11.31.1106 or later is installed on legacy Integrity systems,
dm_raid_adapter is never launched regardless of the diag mode.
HPUXRAIDSAIndicationProviderModule always monitors natively the hardware and generates
WBEM events. The reverse wrapper, RAID_WbemWrapperMonitor, may be launched
depending on the connected hardware. These reverse wrappers convert the WBEM event to
the corresponding EMS event.
The introduction of this native support adds to support the following EMS resource path:
/adapters/events/raid_wbem_wrapper
On the other hand, as the process for disk_em and msamon_sas are never launched, the
corresponding EMS resource path are not monitored:
/adapters/events/raid_adapter
• Problem: No e-mail alerts for the subscription.
Description: Users will not receive e-mail alerts for existing and new e-mail subscriptions due
to database authorization issue in September 2011 release.
Workaround: There is no workaround for this problem.
Following is the limitation of the RAIDSA provider:
• It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related Documentation
Table 9 lists the available documentation for the WBEM providers:
Table 9 WBEM Provider Related Documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the Indication Schema
Datasheets of all the providers are installed along with the product at the following
location on the system:/opt/<provider-name>/doc
Provider Datasheets
The datasheets are also available at the following location:
www.hp.com/go/hpux-networking-docs and select HP-UX 11i WBEM Software
collection.
10 HP-UX WBEM RAIDSA Provider release notes