HP-UX WBEM RAIDSA Provider Release Notes (5900-1495, March 2011)
Table 7 Defects Fixed in the HP-UX 11i v3 OS (continued)
In the previous release, on BL870c i2 platform, the RAIDSA disk test command:
#/opt/raidsaprovider/lib/RAID_Provider_Test -d fails to generate
events for all subsequent RAIDSA disks available on the system if the first
instance of the disk is not supported by the
HPUXRAIDSANativeIndicationProviderModule.
This defect is fixed in the current release on BL870c i2 platform. The disk test
is enhanced to send events for all the monitored paths even if the first instance
of the disk is not supported by the
HPUXRAIDSANativeIndicationProviderModule.
QXCR1001058688
In the previous release, the HPUXRAIDSAIndicationProviderModule
displays incorrect severity value after registering with EMS sub-system on HP-UX
11i v3 OS. The moncheck utility output, used to view the status of OnlineDiag
monitors, displays incorrect severity value.
This defect is fixed in the current release. The
HPUXRAIDSAIndicationProviderModule displays appropriate severity
value after registering with EMS sub-system on HP-UX 11i v3 OS.
QXCR1001048021
In the previous release on HP-UX 11i v3 OS, enumeration of classes available
in RAIDSA Instance provider and RAIDSA Consolidated Status provider fails
for a user with non-root privileges.
This defect is fixed in the current release. Enumeration of classes available in
RAIDSA Instance provider and RAIDSA Consolidated Status provider is successful
even for a normal user.
QXCR1001068706
In the previous release on BL870c i2 platform, when the cimserver /
HPUXRAIDSANativeIndicationProviderModule is restarted, the
Indication Identifier index is reset. If the evweb current database already has
events with the same event number or Indication Identifier index, such duplicate
events are not logged in the evweb database. When events with the same IDs
are reported frequently, the events will be logged in the /var/opt/sfm/log/
event.log file and the syslog file.
In the current release on BL870c i2 platform, when the cimserver /
HPUXRAIDSANativeIndicationProviderModule is restarted, the
Indication Identifier is concatenated with a timestamp along with the event
number and Index. With this modification, the Indication Identifier can never
be duplicated and all the event IDs generated by the
HPUXRAIDSANativeIndicationProviderModule are unique, which gets
logged in the evweb database.
QXCR1001078598
Known Problems, Workarounds, Limitations
There are no known problems and workarounds in the current release.
Following is the limitation of the RAIDSA provider:
• It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related Documentation
Table 8 lists the available documentation for the WBEM providers:
Table 8 WBEM Provider Related Documents
LocationDescription
http://www.dmtf.org/education/cimtutorial.phpCIM Tutorial
http://software.hp.com
and
http://www.hp.com
Information about HP WBEM Services
Known Problems, Workarounds, Limitations 9