HP-UX WBEM Mass Storage Providers Release Notes, September 2008

Defects Fixed in This Version
The following defects are fixed in the Mass Storage providers for September 2008 release. To
view the entire details of each defect fix, refer to the HP IT Resource Center at: http://
forums1.itrc.hp.com/service/forums/home.do
Table 1-3 September 2008 Defect Fixes for HP-UX 11i v2 and HP-UX 11i v3 OS
DescriptionDefect ID
RAIDSA Provider generates a core when the ioctl call fails, and the number of file
descriptors opened are more than the maximum number of file descriptors that can be
opened. This scenario is an exception case which is observed only when the ioctl call fails
multiple times. This defect is fixed on HP-UX 11i v3 OS.
QXCR1000768317
The SMH web page reports system status as Major when SCSI cards are not installed on
HP-UX 11i v3 OS. This defect is fixed and the status is displayed as OK on the SMH web
page when SCSI cards are not installed.
QXCR1000805651
The Fibre-Channel Consolidated Status Provider (FC-CSP) reports incorrect operational
status if FC cards are not installed on HP-UX 11i v3 OS. This defect is fixed and the provider
reports the consolidated status as OK if FC cards are not installed on HP-UX 11i v3 OS.
QXCR1000805664
The getInstance( ) method fails for non-mpt based SCSI Card on HP-UX 11i v3 OS.
This defect is fixed and the getInstance( ) method returns values for non-mpt based
SCSI card.
QXCR1000817243
In the SMH web page, the SCSI HBA shows virtual HBA with mpt only. The vHBAs with
gvsd driver is not displayed on HP-UX 11i v3 OS. This defect is fixed, and the vHBAs with
gvsd driver is displayed.
QXCR1000810886
The LAN Indication provider prevents I/O deletion by the olrad operation on HP-UX 11i
v3 OS. This defect is fixed and the olrad command can now perform I/O deletion even if
the LAN Indication provider is installed on the system.
QXCR1000585416
In the Fibre-Channel provider, the property type of the class HPUX_FCControlledBy is
changed to a string type from a reference type.
QXCR1000749487
The RAIDSA provider was not supporting some RAIDSA HBA model numbers that were
supported by the driver. This defect is fixed in the current release and the provider handles
all model numbers that are supported by the driver. The provider logs a message for any
unsupported model number as Unsupported HBA with model number %d.
QXCR1000819792
The debugging trace log was enabled by default for RAIDSA and SAS providers. This defect
is fixed and the debugging trace log is disabled for RAIDSA and SAS providers.
QXCR1000819510
Known Problems, Workarounds, Limitations
There are no known problems and workarounds in the current release.
Following are the limitations of the WBEM Providers:
The IOTree Instance Provider does not support enumerateInstances and getInstance
methods for the association classes.
All the instance providers are read-only providers. The providers do not allow users to
modify, create, or delete instances.
The IOTree Indication Provider generates events for hot-swappable slots only.
HP-UX WBEM SCSI Provider supports GVSD based SCSI vHBAs. For GVSD based SCSI
vHBAs, the properties: Maximum Size, Maximum Width, Maximum Targets Controlled,
Supported Signal Capability, and Current Speed are not applicable. They will either be
displayed as NA or 0.
Related Documentation
Table 1-4Lists the available documentation for the WBEM providers:
10 HP-UX Mass Storage WBEM Providers Release Notes