HP-UX WBEM LAN Provider Release Notes (766965-001, March 2014)

Defect fixes in B.11.31.1004
Table 7 B.11.31.1004
DescriptionDefect ID
In the previous release, failure messages generated by the
HPUXLANCSProviderModule are logged in /var/adm/syslog/syslog.log
file.
QXCR1000965312
In the current release, these failure messages are not generated by the
HPUXLANCSProviderModule.
In the previous release, enumerate instances method initiated for
HPUX_EthernetGroupHostedCollection class returned CIM_ERR_FAILED,
when non-root guest user executed the method using wbemexec command.
QXCR1000990126
This issue has been fixed in this release.
The enumerate instances method initiated for
HPUX_EthernetGroupHostedCollection class returns instance of the class when
non-root guest user executes the method using wbemexec command.
For more information about the command, see wbemexec(1) man page.
In the previous release, the HPUXLANProviderModule dumps core in certain
scenarios on PA-RISC systems.
QXCR1000985457
This issue has been fixed in this release.
In the previous release, on PA-RISC systems when modify instance method is
initiated for an instance of HPUX_LANMemberOfPolicyCollection class, the LAN
Consolidated Status provider dumps core.
QXCR1000991396
This issue has been fixed in this release.
This defect is fixed in this release on PA-RISC systems.
Defect fixes in B.11.31.1009
Table 8 B.11.31.1009
DescriptionDefect ID
In the previous release, LAN indication provider does not display multiple IP addresses
of a system.
QXCR1001023213
In the current release, LAN indication provider displays multiple IP addresses of a
system.
Defect fixes in B.11.31.1009.01
Table 9 B.11.31.1009.01
DescriptionDefect ID
In the previous release, events are not generated on the primary LAN interface by the
HPUXEthernetIndicationProvider module when APA is configured on HP-UX
system.
QXCR1001054625
This issue has been fixed in this release.
Events are generated on APA ports.
In the previous release, several property data types of the LAN Provider module
are different from the data types documented in the provider datasheet available
QXCR1001043514
at/opt/lanprovider/doc/HPUX_LANProvider.pdf. Property data types used
in the LAN provider module must be reset in accordance to the property data types
set in the datasheet. Users developing WBEM client applications must be aware of
the mismatch of property data types that exist between the provider module and the
provider datasheeet. Following properties are to be reset in the LAN provider module
HPUX_EthernetPort class:
Defects fixed in various versions 9