HP-UX WBEM LAN Provider release notes (5900-2056, March 2012)

Known problems, workarounds and limitations
The following known problems are for the current release:
Problem: There are no email alerts for the subscription.
Description: User do not receive email alerts for existing and new email subscriptions due to
database authorization issue in September 2011 release.
Workaround: There is no workaround for this problem.
Following are the limitations of the LAN provider:
LAN is a read-only provider and hence does not allow users to modify, create, or delete
instances.
In LANInstanceProvider a new error has been introduced. If during instance
(enumerateInstance/getInstance/enumearateInstanceNames)request the
provider is busy retrieving the properties of CIMInstance classes then it will report an error
called CIM_ERR_FAILED: enumerateInstances:: Internal error occurred while building the LAN
inventory.
When LANInstanceProvider gets disabled and enabled manually (cimprovider -dm/-em)
then after getting enabled, for the first instance request the following error can be seen.
CIM_ERR_FAILED: enumerateInstances:: Internal error occurred while building the LAN inventory
When LANIndicationProvider is running, any instance request issued in 10 minutes (maximum)
after the LANInstanceProvider gets enabled will not report the above mentioned error.
When LANIndicationProvider is not running, only the first instance request will fail with the
above mentioned error. The subsequent instance requests will pass without any fail.
If the LANInstanceProvider on the guest is disabled, the host shows the guest related information
for a maximum 70 minutes. After that instance request on host will not show the guest owned
DIO functions until maximum of 60 minutes after the provider gets enabled again.
If the guest system is shutdown then the guest DIO function might be seen in the instance
request output for a maximum time of 10 minutes. After that no DIO functions for the turned
off guest will be seen for that guest until the guest is not turned on again.
Related documentation
Table 9 lists the available documentation for the WBEM providers:
Table 9 WBEM provider related documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the indication schema
The Datasheets are available at the following location:Provider Datasheets
www.hp.com/go/hpux-networking-docs and select HP-UX 11i WBEM Software
collection.
Localized version of the software
The product is supported only in English locale (LANG=C). Behavior of the product is unpredictable
when LANG value is set to any other language code other than C. Documentation support for this
product is also available only in English locale.
10 HP-UX WBEM LAN provider release notes