HP-UX WBEM LAN Provider Release Notes (5900-1604, April 2011)
Table 5 Defects Fixed in the HP-UX 11i v3 operating systems. (continued)
DescriptionDefect ID
In the previous release, several property data types of the LAN Provider module are different
from the data types documented in the provider datasheet available at/opt/lanprovider/
doc/HPUX_LANProvider.pdf. Property data types used in the LAN provider module must
be reset in accordance to the property data types set in the datasheet. Users developing
WBEM client applications must be aware of the mismatch of property data types that exist
between the provider module and the provider datasheeet. Following properties are to be
reset in the LAN provider module HPUX_EthernetPort class:
Table 6 Class HPUX_EthernetPort Properties
To TypeFrom TypeProperty Name
uint16[]Sint32OperationalStatus
uint64uint32Speed
uint64Sint32ActiveMaximumTransmissionUnit
string[]StringNetworkAddresses
uint32Sint32MaxDataSize
Following properties are to be reset in the LAN provider module
HPUX_EthernetLANEndpoint class:
Table 7 Class HPUX_EthernetLANEndpoint Properties
To TypeFrom TypeProperty Name
uint16[]Sint32OperationalStatus
uint16Sint32ProtocolType
In the current release, this defect is fixed. Property data types are reset in the LAN provider
module HPUX_EthernetPort and HPUX_EthernetLANEndpoint classes.
QXCR1001043514
Defect Fixes in B.11.31.1103 Release
In the previous release, the HPUXEthernetIndicationProvider module dumps core on
HP-UX system when the module is restarted and the LAN port is reset simultaneously.
This defect is fixed in the current release. The HPUXEthernetIndicationProvider module
does not dump core on HP-UX system when the module is restarted and the LAN port is reset.
QXCR1001055304
Defect Fixes in B.11.31.1103.01 Release
In the previous release, the HPUXEthernetIndicationProvider module does not generate
events related to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE
Mezzanine adapter on BL870c i2 platform.
In the current release, the HPUXEthernetIndicationProvider module generate all events
related to HP 580151-B21 10Gb PCIe 2-port OCm10102-F-HP FCoE Mezzanine
adapter on BL870c i2 platform.
QXCR1001021582
Known Problems, Workarounds, Limitations
The following known problem is for the current release:
When a new APA interface is created after starting HPUXEthernetIndicationProvider
module, indication is not generated for the event. Indications are generated during subsequent
additions and deletions of the newly created APA.
Known Problems, Workarounds, Limitations 7