HP-UX WBEM LAN Indication Provider Datasheet, April 2010

Page 6 of 8
Created on 5/26/10
0
Unknown
26
LAN
Error
lan<ppa>
link has
gone down.”
“The link has gone down for
an unknown reason.”
[“
If the interface does not return back to its
normal operating state on its own try these
other actions, in the order listed here, until the
problem is resolved.”]k
[“Verify that the link partner is operating
normally.”]
[“Verify that the link settings on this adapter
are compatible with the corresponding settings
on its link partner.”]
[“If this interface is directly connected to
another Ethernet adapter with a copper cable,
ensure that a cross-over cable is used for
speeds less than 1000 Mb/s.”]
[“Try resetting the card using lanadmin -r
<ppa>.”]
[“Verify that the cable from this interface to its
link partner is not defective.”]
[“Replace The NIC.”]
5
4
--
Minor
26
LAN
Error
“Temporarily
quiescing
indications for an
event.”
“The event i
s occurring
frequently and has exceeded
an internal threshold.”
[“Follow the actions for the events that were
reported recently on this interface. This event
will not be reported again until the rate at
which it occurs drops below an internal
threshold.”]
7
Severity
ProbableCause
Description
CauseDescription
Recommended Actions
Event
ID
2
Informational
1
Other
lan<ppa>
l
ink is
now up.”
“The link is now up.
[“No action is necessary. The
interface
is
operating normally.”]
6
Associations provided by this provider
This provider does not currently support any associations.
Links to more information
Additional provider documentation
There is currently no additional documentation for this provider beyond this information.
See also man pages for information on the various commands and system calls noted in the descriptions
above.
WBEM information
For a CIM tutorial, go to http://www.dmtf.org/education/tutorials.
For information about HP WBEM Services for HP-UX, see software.hp.com and hp.com (the Network and
Systems Management areas).