HP-UX WBEM Fibre-Channel Provider Release Notes (April 2010, 5992-5218)
Table 10 Defects Fixed in the HP-UX 11i v3 OS (continued)
DescriptionDefect ID
In the current release, this defect is fixed. As a result, events reported by the
HPUXFCIndicationProviderModule are not lost even if event subscriptions are created
by a non-privileged user.
Defects Fixed in B.11.31.1004 Release
In the previous release, during installation of Fibre-Channel provider, the /prod_info/
FCP-NIP-RUN/configuration file contained RAIDSA provider related message.
In the current release, the /prod_info/FCP-NIP-RUN/ configuration file is modified to
display Fibre-Channel provider related message.
QXCR1000995013
In the previous release, events generated by all I/O Indication providers were logged in
Fibre-Channel provider database FCPROVDB, available at the location:/opt/psb/db/pgsql/
bin/psql .
QXCR1001013221
In the current release, events generated only by Fibre-Channel Indication provider gets logged
in the FCPROVDB database, available at the location: /opt/psb/db/pgsql/bin/psql.
In the previous release, following fields were not populated with appropriate values from the
indications generated by HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule:
QXCR1001012655 /
QXCR1000996830
• Event Threshold
• Event TimeWindow
• SystemSerialNumber
• SystemFirmwareVersion
• SystemGUID
In the current release, these fields are populated from the indications generated by
HPUXFCIndicationProviderModule and
HPUXFCNativeIndicationProviderModule.
In the previous release, after OE install, reboot, or upgrade, the Fibre-Channel Indication
module times-out while registering with EMS.
QXCR1001001392
In the current release, this defect is fixed by increasing the time-out value of EMS registration.
In the previous release, system log configuration file for Fibre-Channel provider available at:
/var/opt/fcprovider/conf is termed as PSBLoggerConfig.xml.
In the current release, the log configuration file for Fibre-Channel Provider available at: /var/
opt/fcprovider/conf is termed as FCLoggerConfig.xml.
QXCR1000947233
In the previous release, Memory leak encountered due to ComponentData Indication
properties of HPUXFCIndicationProviderModule.
QXCR1001016011
In the current release, this defect is fixed.
In the previous release, the moncheck displayed an illegal severity level as "??"QXCR1000965458
This defect is fixed in the current release. The provider registers with the ems Registrar for
events with severity greater than or equal to 1.
Known Problems, Workarounds, Limitations
There are no known problems and workarounds for the current release:
Following is the limitation of the FC provider:
• It is a read-only provider and hence does not allow users to modify, create, or delete instances.
Related Documentation
Table 7 lists the available documentation for the WBEM providers:
10 HP-UX WBEM Fibre Channel Provider Release Notes