HP-UX WBEM Fibre Channel Provider release notes (5900-2518, March 2013)

Table 8 Defect fix in the HP-UX 11i v1 OS (continued)
DescriptionDefect ID
Defect fix in B.11.11.08 release
In the current release, this defect is fixed and the FCIndicationProvider process does
not cause memory leak.
Defect fix in B.11.11.09 release
After you upgrade to FCProvider B.11.11.08 version, the FD leak in the FCProvider
caused the system to hang.
QXCR1001193817
In the current release, this defect is fixed and there is no FD leak in the FCProvider.
Table 9 Defects fixed in the HP-UX 11i v2 OS
DescriptionDefect ID
Defects fixed in B.11.23.1003 release
In the previous release, when event subscriptions are created by a non-privileged user, the
HPUXFCIndicationProviderModule runs out of file descriptors and stops functioning.
As a result, events reported by the HPUXFCIndicationProviderModule may be lost.
QXCR1000897995 /
QXCR1000988741
In the current release, this defect is fixed. As a result, events reported by the
HPUXFCIndicationProviderModule are not lost even if event subscriptions are created
by a non-privileged user.
The Fibre-Channel indication provider generate events for the following three types of
Fibre-Channel adapters or monitors:
QXCR1000991458
dm_ql_adapter
dm_fclp_adapter
dm_TL_adapter
In the previous release, the event IDs of the generated events are not unique across the three
monitors. Due to this, the generated events cannot clearly describe the source of indication.
In the current release, Fibre-Channel indication provider generate indications from the respective
monitors. When an Event Monitoring System (EMS) event is received, the ProviderName field
value is set as follows depending on the name of the monitor.
For example:
The dm_ql_adapter monitor has the provider name field value as:
HPUXFCDIndicationProvider.
The dm_fclp_adapter monitor has the provider name field value as:
HPUXFCLPIndicationProvider.
The dm_TL_adapter monitor has the provider name field value as:
HPUXTDIndicationProvider.
Based on the provider name and event ID of the generated events, users can identify the
source and type of indication.
Defect fixed in B.11.23.1004 release
Fibre-Channel indication provider module consumes SAS EMS events and generates WBEM
indications using these events. The provider name used in Fibre-Channel indication module
is HPUXSASIndicationProvider.
QXCR1000798702
In the previous release, incorrect hardware path and World Wide Number (WWN) of the
hardware are displayed on System Management Homepage (SMH) for a dual/multi port
Fibre-Channel Card.
In the current release, this defect is fixed. On HP–UX 11i v2 OS, two tables namely FC Ports
and FC Controllers are displayed on the SMH page. The FC Controllers table displays
QXCR1001017067
information about the physical cards on the machine. The FC Ports table displays information
about the individual ports.
Defect fixed in B.11.23.1012 release
Defects fixed in this version 9